background image

Instruction manual

2. Edition, May 2021

P/N 01721-24983

From Decoder Firmware 3.0.9

51832 SwitchPilot 3 Servo

SwitchPilot 3 Servo

SWitch Pilot

Summary of Contents for 51832

Page 1: ...Instruction manual 2 Edition May 2021 P N 01721 24983 From Decoder Firmware 3 0 9 51832 SwitchPilot 3 Servo SwitchPilot 3 Servo SWitch Pilot...

Page 2: ...figuring outputs 17 6 4 1 Servo position und mode 17 6 4 2 Servo speed and relay response time 18 6 4 3 Servo seesaw effect Bouncing 18 6 5 Servo pulse configuration 18 6 6 Function Mapping 19 Content...

Page 3: ...itt dienen Lieferm glichkeiten und alle sonstigen Rechte vorbehalten Elektrische und mechanische Ma angaben sowie Abbildungen ohne Gew hr Jede Haftung f r Sch den und Folgesch den durch nicht bestimmu...

Page 4: ...the decoder Therefore a request Please carefully work through this manual prior to commissioning Although all SwitchPilot decoders are very robust a wrong con nection could destroy the device If in do...

Page 5: ...commands instead of the re quired accessory commands As a special feature the SwitchPilot 3 Servo can be used entirely without a digital center if desired up to 16 buttons can be con nected for direc...

Page 6: ...e In digital mode and subject to the settings of the control panel every servo can move to two end positions A and B With the SwitchPilot 3 Servo you can adjust both end positions as well as the speed...

Page 7: ...13 14 15 16 time on off RED ON RED OFF GREEN ON GREEN OFF Turns to A Speed A Pos A Turns to B Speed B Pos B Figure 3 Proportional mode keyboard 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 time on off RED O...

Page 8: ...adjusted even if there is no external impulse These servos also tend to hum when not in use because the external actuating forces are through the motor should be com pensated A digital servo only come...

Page 9: ...mmend an external power supply particularly for larger layouts because then the energy for powering the drives does not add to the load for the command station or booster c Connect the Terminals Trk A...

Page 10: ...pter 9 5 3 External power supply For larger layouts with many electric loads we recommend the use of an external power supply DC and AC power supplies are suitable with the specifications described in...

Page 11: ...Pilot 3 Servo supplies them with 5V Figure 7 shows the general con nection Figure 7 Servo connection Simply plug the connection cable of the servo into the correspon ding socket on the SwitchPilot ser...

Page 12: ...outputs 5 to 8 5 5 1 Relay outputs Fig 8 shows the connections a The outputs 1 to 4 are connected to relay outputs A and B which are activated jointly 2x change over contacts bistable Each relay outpu...

Page 13: ...13 5 5 2 Turnout frog polarization With the SwitchPilot Exension module turnout frogs can be po larized very easily Wiring the outputs Figure 9 Polarization with SwitchPilot Extension...

Page 14: ...ons and or throttles respectively central units support POM for accessory decoders or forgotten addresses of decoders installed on the layout Even assigning the decoder address presented many model ra...

Page 15: ...sired turnout numbers for output 1 to 4 The currently selected turnout numbers are displayed flashing e Press the PROG OK button again to confirm the turnout numbers for outputs 1 to 4 The display no...

Page 16: ...he and buttons you can scroll between the individual panels a Name of the panel b Name of setting option 1 c Value of the setting option 1 d Name of setting option 2 e Value of the setting option 2 f...

Page 17: ...n method to calculate the turnout num bers from the accessory addresses Set the decoder to ROCO to ensure that the SwitchPilot 3 handles instructions from ROCO command stations correctly To do this se...

Page 18: ...me for activating the relay once the servo has reached the centre position between the two end positions A and B The precise switching time depends on the desired regulating time of the servo Delay On...

Page 19: ...ing after reaching the end position Subject to design construction and configuration of the servo other combinations of the above three options are feasible If in doubt simply try it out for reliably...

Page 20: ...voltage otherwise the voltage of the connected power supply Status information INFORMATION HW 3 0 FW 3 0 9 Voltage 17 3V 6 7 2 Displaying the status of the outputs The Output State table provides impo...

Page 21: ...est PC software for your LokProgrammer but at least version 5 1 0 To ensure a correct reading connect the SwitchPilot 3 Servo as shown in Fig 11 Pw A and Pw B Figure 11 SwitchPilot connection to LokPr...

Page 22: ...decoder and read them subject to the capabilities of the command station With the ECoS this is done as follows Go to the main programming menu of the ECoS Select POM DCC and Accessory decoder Select t...

Page 23: ...accessories are switched you can find out in the manual of your command station or the handheld throttle Once the switch command has been understood by the Switch Pilot the new address is saved and t...

Page 24: ...t switching 12 Direct switching with the inputs for push buttons The SwitchPilot 3 Servo is also suitable for switching the 8 servo outputs without a digital system Therefor it may also be used by the...

Page 25: ...to resto re the factory default values directly In the Do Reset option select Yes and confirm with PROG OK The display will flicker briefly after which the SwitchPilot will be restored to have factory...

Page 26: ...Delay On Speed A 0 63 Adjustment speed on the way to A Speed B 0 63 Adjustment speed on the way to B SPE REL Delay On Delay Off 05 SERVO 1 BOUNCING Bouncing Pos A B Bounces 0 Strength 0 Bouncing Disab...

Page 27: ...s B 40 Mode Digital Pos A 0 63 Servo 4 End position A Pos B 0 63 Servo 4 End position B Mode Digital Proportional 13 SERVO 4 SPEED Speed A 40 Speed B 40 SPE REL Delay On Speed A 0 63 Adjustment speed...

Page 28: ...ces 0 Strength 0 Bouncing Disabled Pos A Pos B Pos A B Bounces 0 31 Strength 0 31 21 SERVO 7 POSITION Pos A 24 Pos B 40 Mode Digital Pos A 0 63 Servo 7 End position A Pos B 0 63 Servo 7 End position B...

Page 29: ...ervo should be switched with turnout number 1 28 FUNCTION MAPPING F2 Servo 1234 5678 Servo Which servo should be switched with turnout number 2 29 FUNCTION MAPPING F3 Servo 1234 5678 Servo Which servo...

Page 30: ...ys Imp On Always On CMD Imp Off Never Timeout PWR Always On Move 36 RAILCOM Mode Enabled CH2 Enabled Mode Enabled Disabled CH2 Enabled Disabled 37 RESET DECODER Do Reset No Do Reset No Yes 38 INFORMAT...

Page 31: ...134 135 136 34 34 0 Solenoid address turnout numbers Turnout numbers Address CV1 CV 9 137 138 139 140 35 35 0 141 142 143 144 36 36 0 145 146 147 148 37 37 0 149 150 151 152 38 38 0 153 154 155 156 3...

Page 32: ...408 102 38 1 409 410 411 412 103 39 1 413 414 415 416 104 40 1 417 418 419 420 105 41 1 421 422 423 424 106 42 1 425 426 427 428 107 43 1 429 430 431 432 108 44 1 Turnout numbers Address CV1 CV 9 433...

Page 33: ...No data transmission on channel 2 Data transmission allowed on channel 2 0 2 29 Configuration register DCC configuration settings for the SwitchPilot 128 136 128 Bit Description Value 136 3 RailCom co...

Page 34: ...ervo with power when it is to be moved 4 44 Function Mapping F1 Servos that switch at turnout number 1 0 255 1 Bit Description Value 0 Servo 1 1 1 Servo 2 2 2 Servo 3 4 3 Servo 4 8 4 Servo 5 16 5 Serv...

Page 35: ...tes the pulse length that is sent to the servo 0 63 40 115 Servo 1 speed B Running time speed of rotation towards end position B Running time is a multiple of 0 25 seconds 1 0 25s 63 15 75s 0 63 15 11...

Page 36: ...o 3 Bounces as CV 116 0 31 0 133 Servo 3 Strength as CV 117 0 31 0 134 Servo 3 Optionen as CV 118 0 31 0 136 Servo 4 Speed A as CV 112 0 63 15 137 Servo 4 Pos A as CV 113 0 63 24 138 Servo 4 Pos B as...

Page 37: ...160 Servo 7 Speed A as CV 112 0 63 15 161 Servo 7 Pos A as CV 113 0 63 24 162 Servo 7 Pos B as CV 114 0 63 40 163 Servo 7 Speed B as CV 115 0 63 15 164 Servo 7 Bounces as CV 116 0 31 0 165 Servo 7 Str...

Page 38: ...38 Change history 18 Change history 2 Edition March 2021 Spelling mistake corrected 1 Edition December 2020 Initial Document...

Page 39: ...the enclosed failure report card as detailed and precise as possible and return it with your faulty product Please use the appropriate postage when shipping to ESU Extend of warranty exclusions This...

Page 40: ...Phone Date Signature 2 Error Transistor outputs Short circuit Servo outputs No function from the start No Function Programming on the Main 3 Error description 4 Receipt Please enclose your receipt in...