30
No Screen
Options
33
FUNCTION MAPPING F7
Servo : .... ..».
1234 5678
Servo: Which servo should be switched with turnout number 7
34
FUNCTION MAPPING F8
Servo : .... ...»
1234 5678
Servo: Which servo should be switched with turnout number 8
35
SERVO CONTROL
Imp On : Always
Imp Off : Never
PWR : Always
Imp On : Always | On CMD
Imp Off: Never | Timeout
PWR : Always | On Move
36
RAILCOM
Mode : Enabled
CH2 : Enabled
Mode: Enabled | Disabled
CH2 : Enabled | Disabled
37
RESET DECODER
Do Reset: No
Do Reset: No | Yes
38
INFORMATION
HW : 3.0
SW : 3.0.9
Voltage : 18.4V
HW: Hardware version of the decoder.
SW: Software version of the decoder. Update with LokProgrammer
Voltage: Supply voltage of the decoder (if necessary rail tension)
39
OUTPUT STATE
1 2 3 4 5 6 7 8
CMD .».»».».»..».»».
END .».»..».»....»».
Menu references SwitchPilot 3 Servo