background image

18

Turnout number

Address

CV1

CV9

41

42

43

44

11

11

0

45

46

47

48

12

12

0

49

50

51

52

13

13

0

53

54

55

56

14

14

0

57

58

59

60

15

15

0

61

62

63

64

16

16

0

65

66

67

68

17

17

0

69

70

71

72

18

18

0

73

74

75

76

19

19

0

77

78

79

80

20

20

0

81

82

83

84

21

21

0

85

86

87

88

22

22

0

89

90

91

92

23

23

0

93

94

95

96

24

24

0

97

98

99

100

25

25

0

101

102

103

104

26

26

0

105

106

107

108

27

27

0

109

110

111

112

28

28

0

113

114

115

116

29

29

0

117

118

119

120

30

30

0

121

122

123

124

31

31

0

125

126

127

128

32

32

0

129

130

131

132

33

33

0

133

134

135

136

34

34

0

137

138

139

140

35

35

0

141

142

143

144

36

36

0

145

146

147

148

37

37

0

149

150

151

152

38

38

0

153

154

155

156

39

39

0

157

158

159

160

40

40

0

161

162

163

164

41

41

0

165

166

167

168

42

42

0

Turnout number

Address

CV1

CV9

169

170

171

172

43

43

0

173

174

175

176

44

44

0

177

178

179

180

45

45

0

181

182

183

184

46

46

0

185

186

187

188

47

47

0

189

190

191

192

48

48

0

193

194

195

196

49

49

0

197

198

199

200

50

50

0

201

202

203

204

51

51

0

205

206

207

208

52

52

0

209

210

211

212

53

53

0

213

214

215

216

54

54

0

217

218

219

220

55

55

0

221

222

223

224

56

56

0

225

226

227

228

57

57

0

229

230

231

232

58

58

0

233

234

235

236

59

59

0

237

238

239

240

60

60

0

241

242

243

244

61

61

0

245

246

247

248

62

62

0

249

250

251

252

63

63

0

253

254

255

256

64

0

1

257

258

259

260

65

1

1

261

262

263

264

66

2

1

265

266

267

268

67

3

1

269

270

271

272

68

4

1

273

274

275

276

69

5

1

277

278

279

280

70

6

1

281

282

283

284

71

7

1

285

286

287

288

72

8

1

289

290

291

292

73

9

1

293

294

295

296

74

10

1

297

298

299

300

75

11

1

Turnout number, addresses & CVs of the first 552 turnouts

Summary of Contents for 51801

Page 1: ...Instruction Manual 4 Edition December 2017 P N 04213 13564 SwitchPilot V2 0 SwitchPilot Extension V1 0 SwitchPilot V2 0...

Page 2: ...zing electric frogs 13 7 Decoder settings programming 14 7 1 Changeable decoder settings 14 7 1 1 Configuration Variables CV 14 7 1 1 1 Standardization regarding NMRA 14 7 1 1 2 Bits und Bytes 14 7 2...

Page 3: ...ot suitable for children under 14 years of age Inappropriate use may result in injury due to sharp points and edges M rklin and mfx is a registered trademark of the company Gebr M rklin and Cie GmbH G...

Page 4: ...as outlined in this manual for wiring any external components Other circuitry may cause da mage to the SwitchPilot SwitchPilot is not water proof It is not intended for outside use If you use this pro...

Page 5: ...021 Central Station or with DCC compliant command stations SwitchPilot Decoders are able to control all current DCC program ming modes and can be set up either on the main track or the programming tra...

Page 6: ...equested the pulse signal can be disabled when the end po sition of the lever is reached Furthermore the power supply to each servo can be interrupted to prevent any twitching of some cheaper servos D...

Page 7: ...e du ration Subject to the pulse duration and also in continuous mode it may happen that several outputs are on at the same time Please note that the total current of all connected loads must not exce...

Page 8: ...on your layout 6 1 Connecting elements of the SwitchPilot Figure 1 shows the SwitchPilot a Wire turnouts signals un couplers or similar devices to the ter minals of the transistor outputs 1 to 4 The t...

Page 9: ...Separate power supply For larger layouts with many devices controlled by SwitchPilots and simultaneously active we recommend to utilise a separate power supply in this manner the power for switching t...

Page 10: ...The needed ground solder pad is not available on all SwitchPilot sur faces 6 4 2 Wiring daylight signals and light bulbs or LEDs If you use daylight signals with incandescent lamps light bulbs or LEDs...

Page 11: ...d They must have a three pole terminal and operate on a positive pulse The SwitchPilot provides 5V to the servo Simply insert the wire from the servo into the appropriate socket of the SwitchPilot Gen...

Page 12: ...r servo setting B is reached the terminals II and Com are connected b Terminal with ground and voltage power U DC for the use of DC turnout motors like the Tortoise motor 6 6 2 Wiring a motor drive Th...

Page 13: ...6 6 4 Polarizing electric frogs You may polarize supply power of the correct polarity to the electro frog of your turnout If you would like to use a servo with your turnout it is most often necessary...

Page 14: ...s CV All SwitchPilot decoders follow the CV concept which was deve loped in the United States The name CV Configuration Variable is derived from the fact that the memory cells being described above ar...

Page 15: ...CC norm while some manufacturers e g Lenz count the bits from 1 to 8 Please keep this in mind when programming our decoders with such systems 7 2 1 Programming on the programming track For programming...

Page 16: ...Marklin central unit e g 6021 Mobile Station Central Station is not possible due to the missing DCC format However the most important properties can still be changed The desired turnout numbers can b...

Page 17: ...ing of an address on one hand and that all outputs stay together in one block on the other hand 8 2 Decoder address The desired address is divided internally and put into CV 1 and CV 9 Please never mi...

Page 18: ...3 164 41 41 0 165 166 167 168 42 42 0 Turnout number Address CV1 CV9 169 170 171 172 43 43 0 173 174 175 176 44 44 0 177 178 179 180 45 45 0 181 182 183 184 46 46 0 185 186 187 188 47 47 0 189 190 191...

Page 19: ...40 1 417 418 419 420 105 41 1 421 422 423 424 106 42 1 425 426 427 428 107 43 1 429 430 431 432 108 44 1 Turnout number Address CV1 CV9 433 434 435 436 109 45 1 437 438 439 440 110 46 1 441 442 443 44...

Page 20: ...mal operating mode and the LED extinguishes Should you have programed another turnout instead of the first one of the group of four the correct group will be automatically detected and programed 8 4 2...

Page 21: ...7 10 Features of servo outputs Two end positions A and B as well as a turning speed can be assigned to each servo output You can also define when the pulse signal is sended to the servo and if power s...

Page 22: ...he central unit CV Information The decoder can return all CV values to the cen tral unit via Railcom A programming track will not be necessary in the future 11 1 How to activate RailCom All SwitchPilo...

Page 23: ...e solenoid device with a control panel as described in the ECoS manual in section 13 3 If the current setting does not coincide with the desired setting it will be indicated with a small exclamation m...

Page 24: ...o each relay output Example You would like to operate relay outputs 1 and 2 together with servo outputs 5 6 but relay outputs 3 and 4 should be switched in parallel to transistor outputs 3 4 Therefore...

Page 25: ...r hotline only in case of complex enquiries that can t be dealt with by email or fax The hotline is often very busy and you may encounter delays Rather send an email or fax and also check our website...

Page 26: ...er supply Maximum supply voltage 18V AC or 24V smooth DC Transistor outputs 1 to 4 4 outputs with two transistors each each with 1 5A continuous 2 0A peak 20 seconds Total maximum load of device 2 0A...

Page 27: ...c 2 31 Alternating Out A and Out B are alternately active blinker Duration of On status multiple of 130 msec 32 63 Bi stable k84 compatable either Out A or Out B is active variable 64 4 Configuration...

Page 28: ...munication RailCom communication is switched off 0 RailCom communication is permitted 8 7 Decoder is DCC Accessory Decoder 128 read only cannot be reprogramed 33 Function output status Current status...

Page 29: ...r to store the address 1 63 1 36 Decoder address 2 MSB Higher 3 bits bit 6 8 of the second decoder address for the outputs 5 and 6 Is used in conjunction with CV 35 in order to store the address Value...

Page 30: ...n Value 0 Relay 1 decelerated switch addit SwitchPilot Switches with 2nd addr 1 1 Relay 2 decelerated switch addit SwitchPilot Switches with 2nd addr 2 2 reserved 4 3 reserved 8 50 Impuls Configuratio...

Page 31: ...ise as possible and return it with your faulty pro duct Extend of warranty exclusions This warranty covers free of charge repair or replacement of the faulty part provided the failure is demonstrably...

Page 32: ...outputs 1 4 Short circuit Servo outputs Dead On Arrival no function right out the box No function anymore Programming on programming track 3 Error description 4 Receipt of pay Please return the goods...

Reviews: