Product Dimensions

Cabinet Dimensions

Cabinet opening dimensions shown are for 25" (64.0 cm) 
countertop depth, 24" (61.0 cm) base cabinet depth and
36" (91.4 cm) countertop height.

If installing a range hood or microwave hood combination above 
the range, follow the range hood or microwave hood combination 
installation instructions for dimensional clearances above the 
cooktop surface.

A freestanding range may be installed next to combustible walls 
with zero clearance.

*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal 

cabinet is protected by not less than 

¹⁄₄

" (0.64 cm) flame 

retardant millboard covered with not less than No. 28 MSG 
sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) 
aluminum or 0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance between the top of the 
cooking platform and the bottom of an unprotected wood or 
metal cabinet.

Electrical Requirements

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.

Do not use an extension cord.

Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.

A copy of the above code standards can be obtained from: 
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269.

WARNING: Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. Check with a 
qualified electrician or service technician if you are in doubt as to 
whether the appliance is properly grounded. Do not modify the 
power supply cord plug. If it will not fit the outlet, have a proper 
outlet installed by a qualified electrician.

A. 27

¹⁄₈

" (68.9 cm) depth with handle

28

¹⁄₈

" (71.6 cm) depth with handle (KitchenAid models only)

B. 46

⁷⁄₈

" (119.1 cm) overall height

46" (116.8 cm) overall height (KitchenAid models only)

C. 36" (91.4 cm) cooktop height
D. 29

⁷⁄₈

" (75.9 cm) width

E. 24

¹³⁄₁₆

" (63.0 cm) depth

F. Model/serial rating plate (located on the left side frame behind 

storage drawer panel)

A

B

C

D

E

F

A. 13" (33.0 cm) max. upper cabinet depth
B. 30" (76.2 cm) min. opening width

C. For minimum clearance to top of cooktop, see NOTE*.
D. 30" (76.2 cm) min. opening width

E. Outlet - 8" (20.3 cm) to 22" (55.9 cm) from either cabinet,

5

¹⁄₂

" (14.0 cm) max. from floor

F.

⁷⁄₈

" (2.2 cm) min. required between cutout and cabinet door or 

hinge.

A

B

D

F

E

C

Summary of Contents for RF265LXTB

Page 1: ...potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provid...

Page 2: ...m beyond the bottom of the cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The floor anti tip bracket must be installed To install the anti tip...

Page 3: ...he ground path is adequate Do not use an extension cord Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest editi...

Page 4: ...be revised so the green ground wire of the 4 wire power supply cord is connected to the cabinet See Electrical Connection Grounding through the neutral conductor is prohibited for new branch circuit...

Page 5: ...nt anti tip bracket to wood floor drill two 3 2 mm holes at the positions marked on the bracket template Remove template from floor To mount anti tip bracket to concrete or ceramic floor use a 4 8 mm...

Page 6: ...e cover from range 3 Add strain relief Style 1 Power supply cord strain relief Remove the knockout for the power supply cord Assemble a UL listed strain relief in the opening Tighten strain relief scr...

Page 7: ...t the neutral center wire to the center terminal connector using one of the hex washer head screws Securely tighten screw for proper electrical connection 5 Connect the other 2 wires lines 1 and 2 to...

Page 8: ...icles In an area where local codes prohibit grounding through the neutral 1 Remove the ground link screw from the range frame Save the ground link screw and cup washer Bend the ground link away from t...

Page 9: ...secure the range to the floor Any method of securing the range is adequate as long as it conforms to the standards in the Location Requirements section LevelRange 1 Place rack in oven Place level on...

Page 10: ...ualified technician MovingtheRange When moving range slide range onto cardboard or hardboard to avoid damaging the floor covering If removing the range is necessary for cleaning or maintenance For pow...

Page 11: ...11 ANTI TIP BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall Left edge Top edge...

Page 12: ...W10141166A 2007 All rights reserved 7 07 Printed in U S A...