3-wire connection: Power supply cord

Use this method only if local codes permit connecting cabinet-
ground conductor to neutral wire of power supply cord.

1. Use a ¼" nut driver and remove the hex washer head screws 

from the aluminum terminal blocks.

2. Connect the neutral (center) wire to the center terminal 

connector using one of the hex washer head screws. 
Securely tighten screw for proper electrical connection.

3. Connect the other 2 wires (lines 1 and 2) to the outer terminal 

screws on the terminal block.

4. Tighten strain relief screws.

5. Replace terminal block cover.

Direct Wire Installation: Copper or Aluminum Wire

This range may be connected directly to the fuse disconnect or 
circuit breaker box. Depending on your electrical supply, make 
the required 3-wire or 4-wire connection.

1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip 

the insulation back 1" (2.5 cm) from the end of each wire.

2. Allow enough slack in the wire to easily attach the wiring 

terminal block.

3. Complete electrical connection according to your type 

electrical supply (4-wire or 3-wire electrical connection).

4-wire connection: Direct wire

Use this method for:

New branch-circuit installations (1996 NEC)

Mobile homes 

Recreational vehicles

In an area where local codes prohibit grounding through the 
neutral

1. Remove the ground-link screw from the range frame. Save 

the ground-link screw and cup washer. Bend the ground-link 
away from the range so that it does not contact the range.

2. Connect the bare ground wire to the range using the ground-

link screw and cup washer. The ground wire must be 
attached first and must not contact any other terminal.

3. Loosen (do not remove) the hex washer head screw and 

insert the neutral (white) wire under the screw clamp at the 
bottom of the center position terminal connector.

4. Insert the other 2 wires (lines 1 and 2) under the other 2 screw 

clamps.

5. Securely tighten the hex washer head screws to 

35 lbs-in. (4.0 N-m) minimum torque to make proper 
electrical connection.

6. Tighten the locking ring of the conduit connector.

7. Replace the terminal block cover.

A. Line 1
B. Ground-link

C. Hex washer head screw
D. Silver-colored terminal 

block screw

E. Neutral (center) wire

F. Line 2

G. UL listed strain relief 

and 40- or 50-amp range 
power supply cord

A

B

C

D

E

F

G

3"

(7.6 cm)

1"

(2.5 cm)

A. Ground-link  screw
B. Cup washer

C. Ground-link bent away from range

A. Bare wire from power 

supply cable

B. Line 1

C. Hex washer head screw
D. Silver-colored terminal 

block screw

E. Line 2
F. Neutral (white) wire

G. UL listed strain relief and 

power supply cable

A. Insert wire under screw clamp.
B. Hex washer head screw

A

C

B

A

B

C

D

E

F

G

A

B

Summary of Contents for RF265LXTB

Page 1: ...potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provid...

Page 2: ...m beyond the bottom of the cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The floor anti tip bracket must be installed To install the anti tip...

Page 3: ...he ground path is adequate Do not use an extension cord Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest editi...

Page 4: ...be revised so the green ground wire of the 4 wire power supply cord is connected to the cabinet See Electrical Connection Grounding through the neutral conductor is prohibited for new branch circuit...

Page 5: ...nt anti tip bracket to wood floor drill two 3 2 mm holes at the positions marked on the bracket template Remove template from floor To mount anti tip bracket to concrete or ceramic floor use a 4 8 mm...

Page 6: ...e cover from range 3 Add strain relief Style 1 Power supply cord strain relief Remove the knockout for the power supply cord Assemble a UL listed strain relief in the opening Tighten strain relief scr...

Page 7: ...t the neutral center wire to the center terminal connector using one of the hex washer head screws Securely tighten screw for proper electrical connection 5 Connect the other 2 wires lines 1 and 2 to...

Page 8: ...icles In an area where local codes prohibit grounding through the neutral 1 Remove the ground link screw from the range frame Save the ground link screw and cup washer Bend the ground link away from t...

Page 9: ...secure the range to the floor Any method of securing the range is adequate as long as it conforms to the standards in the Location Requirements section LevelRange 1 Place rack in oven Place level on...

Page 10: ...ualified technician MovingtheRange When moving range slide range onto cardboard or hardboard to avoid damaging the floor covering If removing the range is necessary for cleaning or maintenance For pow...

Page 11: ...11 ANTI TIP BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall Left edge Top edge...

Page 12: ...W10141166A 2007 All rights reserved 7 07 Printed in U S A...

Reviews: