9
3-wire connection: Direct wire
Use this method only if local codes permit connecting ground
conductor to neutral supply wire.
1. Loosen (do not remove) the hex washer head screws and
insert the neutral (white) wire under the screw clamp at the
bottom of the center position terminal connector.
2. Insert the other 2 wires (lines 1 and 2) under the other 2 screw
clamps.
3. Securely tighten the hex washer head screws to
35 lbs-in. (4.0 N-m) minimum torque to make a proper
electrical connection.
4. Tighten the locking ring of the conduit connector.
5. Replace the terminal block cover.
Verify Anti-Tip Bracket Location
1. Pull drawer open to first stop position. Lift front of drawer to
clear white wheels in drawer guides. Remove drawer and set
it aside on a protected surface.
2. Making sure the anti-tip bracket is installed:
■
Look for the anti-tip bracket securely attached to floor.
■
Slide range back so rear range foot is under anti-tip
bracket.
3. If installing the range in a mobile home, you must secure the
range to the floor. Any method of securing the range is
adequate as long as it conforms to the standards in the
“Location Requirements” section.
Level Range
1. Place rack in oven. Place level on rack and check levelness of
range, first side to side; then front to back.
If range is not level, pull range forward until rear leveling leg is
removed from the anti-tip bracket.
On Ranges Equipped with Storage Drawers:
Use
³⁄₈
" drive ratchet and channel lock pliers to adjust leveling
legs up or down until range is level. Push range back into
position. Check that rear leveling leg is engaged in anti-tip
bracket.
On Ranges Equipped with Warming Drawers:
Use channel lock pliers to adjust leveling legs up or down
until range is level. Push range back into position. Check that
rear leveling leg is engaged in anti-tip bracket.
NOTE: Range must be level for satisfactory baking
conditions.
2. Replace the storage drawer (and warming drawer on some
models).
A. Line 1
B. Ground-link
C. Hex washer head screw
D. Silver-colored terminal
block screw
E. Neutral (white) wire
F. Line 2
G. UL listed strain relief
and power supply
cable
A. Insert wire under screw clamp.
B. Hex washer head screw
A
B
C
D
E
F
G
A
B