background image

 

Estate Swing E-SC 1600 / E-SC 1602 Column Mounted Gate Opener Instructions. 

Wiring the Operator Arm(s) 

11 

Single gate opener:  

 

LEFT MOUNT 

 

Motor1 L1-1: 16 AWG Red 

Motor1 L1-2: 16 AWG Black 

Limit1 OL1: Yellow 

Limit1 COM1: Red 

Limit1 CL1: Black 

Single gate opener:  

 

RIGHT MOUNT 

 

Motor1 L1-1: 16 AWG Red 

Motor1 L1-2: 16 AWG Black 

Limit1 OL1: Yellow 

Limit1 COM1: Red 

Limit1 CL1: Black 

Dual gate opener:  

 

Motor1 L1-1: 16 AWG Red 

Motor1 L1-2: 16 AWG Black 

Motor2 L2-1: 16 AWG Black 

Motor2 L2-2: 16 AWG Red 

Limit1 OL1: Yellow 

Limit1 COM1: Red 

Limit1 CL1: Black 

Limit2 OL2: Yellow 

Limit2 COM2: Red 

Limit2 CL2: Black 

If you require the Right mounted gate to open first change wires to: 

Right hand motor

: Motor 1 L1-1: Black, Motor1 L1-2: Red, Limits on  Limit1 block 

Left hand motor

: Motor 2 L2-1: Red, Motor2 L2-2: Black, Limits on  Limit2 block 

Summary of Contents for E-SC 1600 Series

Page 1: ...ctions Instruction Manual for the E SC 1600 E SC 1602 Series WARNING Read all instructions before beginning installation or use of this gate opener This operator exerts a high level of force Exercise...

Page 2: ...ons on large pilasters without the need to provide niches sometimes required to observe the installation dimensions of piston driven devices It consists of an irreversible electro mechanical operator...

Page 3: ...single 5 Amp dual Max Torque Nm 200 Use frequency cycles hour 100 Operating ambient temperature 4 to 131 Deg F Gearmotor weight lbs 35 Protection class IP44 Gate leaf max length ft Up to 16 Gate leaf...

Page 4: ...t 4 5 Cover Bolts 2 6 Cover Blot O Rings 2 7 Motor Wire Gasket 1 8 Manual Clutch Assembly 1 9 Clutch Keys 2 10 Cover Bolt Plugs 2 3 8 Concrete anchors for column 4 Motor Box Contents Motor Arm Content...

Page 5: ...indicated on page 1 Make sure the leaves move smoothly without any irregular friction during entire travel Make sure the hinges are in good condition Ball bearing hinges are ideal for gates weighing...

Page 6: ...and the control box A voltage meter and digital camera may be necessary to run diagnostic checks Hardware to attach control box to fence or column If your transformer is going to be plugged into an ou...

Page 7: ...al release handle For Right hand mounting turn the handle counter clock wise For Left hand mounting turn the handle clock wise In either case when you turn the handle there will be two audible clicks...

Page 8: ...ounted Gate Opener Instructions IMPORTANT Determining Correct Setback 6 PULL TO OPEN operation only This means the gate operator is mounted on the inside of the property and pulls your gate in towards...

Page 9: ...setback from the previous page The base plate can be mounted with the mounting flange facing up or down see right 2 Secure the base plate to the column using screws and a proper anchoring system for...

Page 10: ...tach the straight arm on the motor drive shaft spline and secure it in place 6 Manually release the operator and swing the arm assembly so the gate bracket is on the gate in the closed position The ar...

Page 11: ...ound in a local home supply store Dig a trench perpendicular to the driveway approximately 6 to 8 inches deep and 6 long Hook up a typical garden hose assembled to the first length of pipe as shown Tu...

Page 12: ...k on when you are fin ished with your wiring connections Be sure you are placing your wires in the terminal block correctly Take the terminal block off of the control board to insert wires Hold with s...

Page 13: ...ngs in place 2 Move the gate into the full open position Move the top ring until it is pushing the switch on the top limit switch in 3 Move the gate to the closed position Move the bottom ring until i...

Page 14: ...2 16 AWG Black Limit1 OL1 Yellow Limit1 COM1 Red Limit1 CL1 Black Dual gate opener Motor1 L1 1 16 AWG Red Motor1 L1 2 16 AWG Black Motor2 L2 1 16 AWG Black Motor2 L2 2 16 AWG Red Limit1 OL1 Yellow Lim...

Page 15: ...he gate will re close from the open position after a time set in the programming section OFF Auto Close off ON Dual gate opener 2 motors OFF Single gate opener 1 motor ON Electric Lock being used OFF...

Page 16: ...board Never connect the power wire with the transformer plugged in Contact between the two lead wires even for a second will destroy the transformer Transformers are only warranted if the internal fu...

Page 17: ...ng to 10 5 Press SET button 6 LED shows P3 Press Push 1 to get P3 setting to 30 7 Press SET button 8 LED shows P4 Press Push 1 to get P4 setting to 3 9 Press SET button 10 LED shows P5 Press Push 1 to...

Page 18: ...ot exceed the time the motor take to move from one limit to the other 3 LED shows P3 P3 is the force setting the lower the number the easier the gate will reverse directions when it meets resistance T...

Page 19: ...sing a 6 screw attached the top of the receiver to the post If you are happy with this position use the small provided set screw in the bottom hole to secure the receiver in place 4 Attach the receive...

Page 20: ...an 1 button on 400 different remotes or this could mean all 4 buttons on 100 remotes or anything in between Some choose to program all 4 buttons to a single receiver if they are not using multiple gat...

Page 21: ...desired stop points Adjust the limit switches Lengthen the run time parameter P1 Check setback if setback is incorrect it will limit how far the gate will move If the gate will open but will not close...

Page 22: ...clamps closed however when the terminal clamps are closed there is a small space below them one could mistake as place to insert a wire If this is done then conductivity of the connection will never b...

Page 23: ...ty you will be required to e mail digital photos to the technician This is done in your best interest to save unnecessary shipping expenses and time lost Many times we can come up with solutions to is...

Page 24: ...reclose 3 When stopped mid cycle waiting auto reclose momentary contact will move the gate in the direction opposite what it was moving before stopped 4 When open and counting auto reclose pause time...

Page 25: ...pening momentary contact will have no effect 3 When stopped mid cycle from PUSH 1 or the Receiver momentary contact will open the gate 4 When open with auto reclose on momentary contact will re set pa...

Page 26: ...imits 12VDC CL2 Closed limit for secondary motor normally closed Photo Input for safety eye photo beam connection normally closed GND Ground for photocell power ground for photo connection V 12VDC Max...

Page 27: ...voltage to EL terminals electric lock OP Opening cycle AU Auto reclose countdown CL Closing cycle PH Photo cell disruption Buzzer Obstructions If the gate s come in contact with an obstruction the ga...

Page 28: ...f PHOTO block on gate opener control board 24V Power Negative or GND or PWR of entry device GND terminal of PHOTO block on gate opener control board Push Button Intercoms Normally Open NO or Input INP...

Page 29: ...erminal if using a safety device 12V is not a misprint the V terminal has a 12V output Solenoid Gate Lock Positive Lead of lock A terminal of E_LOCK block on gate opener control board Negative Lead of...