Estate Swing E-SC 1600 / E-SC 1602 Column Mounted Gate Opener Instructions.
Standard System
Overview and Safety Zones
A standard system includes the provided
components of the gate opener. It also should
include safety and security accessories, such
as photo cells or safety loops, that are right
for the individual installation (not included).
IMPORTANT
Preliminary Checks:
To ensure a safe and efficient automated system, make sure the following conditions
are observed.
The gate and post must be suitable for being automated. Check that the structure is
sufficiently strong and rigid, and its dimensions and weights conform to those
indicated on page 1.
Make sure the leaves move smoothly without any irregular friction during entire
travel.
Make sure the hinges are in good condition. Ball bearing hinges are ideal for gates
weighing over 200 lbs. or over
10’
in length.
Make sure the gate is plumb and level.
The gate post must be secured in the ground with concrete. This will prevent the
gate from shifting during installation.
3
1,2
Estate Swing Operator
3
Photocells (not included)
4
Primary
control board
5
N/A
6
Push button opening device (not included)
7
Receiver extension (not included)
8
12Vdc flashing lamp (not included)
9
Positive stop
10
AC transformer
Notes:
1) When laying electrical cables, use appropriate rigid and/or
flexible tube.
2) Do not run any wires in the same conduit as 110 AC
power that may be in the area. This will cause unwanted
interference.