background image

 

 

 

The ESTATE SLIDE operator is supplied with a magnetic limit switch and bracket to be secured 

to the top of the rack, this commands gate movement to stop in the open position.   

 

1.  Move the gate to the open position.  

 

2.  Attach the plate, as shown below (A), to the rack.  

 

3.  Be sure it is lined up with the magnet, as shown below (B), on the side of the operator. The 

red limit light should come on when the magnet is lined up. 

 

4.  After the magnet is lined up, move the gate open for programming. 

 

 

The open stop point will be learned by programming later in the manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Travel Limit Installation for OPEN position 

(A) 

Red part is magnet, face 

toward the operator. 

Sliver part is attached to 

top of rack. 

 

(B) 

This is the limit detector, this should line up with the red  

magnet (A) in the OPEN position. 

 

11 

Summary of Contents for E-SL 450 Series

Page 1: ...Instruction Manual for the E SL 450 Series...

Page 2: ...ro mechanical linear operator powered by a 24V AC transformer coupled with control board that switches the voltage to DC to power the motor The MASTER card can be programmed and is used to set the fol...

Page 3: ...inutes Operating ambient temperature 32 to 104 Deg F Motor Rotational Speed 2000r min Gate leaf max length ft Up to 14 Gate leaf max weight lbs Up to 450 Type of Limit Switch Magnetic Specifications 1...

Page 4: ...ion plugs securing the foundation plate Check if the upper guide and travel limit mechanical stops are installed We advise you to have any metalwork carried out before the automated system is installe...

Page 5: ...me and a trowel Low voltage wire will be required to run power to your operator See the power page for specifications If the gate is more than 144 from an a c power supply then an electrician will be...

Page 6: ...release the lever 2 Lift the lever to disengage the gears 3 The motor will not run again until the motor is relocked There is a magnetic sen sor that allows the motor to operate be sure the magnet is...

Page 7: ...enter of the pad and the other end is easily ac cessible 3 After the foundation has dried use 7 16 concrete anchors attach the opener to the base NOTE The gate opener can be placed on the left or righ...

Page 8: ...stalling the opener to the base 1 Manually take the leaf to its close position 2 Lay the first piece of rack at the appropriate level and mark the hole position on the gate Make a hole and use nuts bo...

Page 9: ...installation Make sure that during the gate travel all the rack elements mesh correctly with the pinion Do not on any account weld the rack elements either to the spacers or to each other When you hav...

Page 10: ...ise is a longer pause time The force of the motor is adjustable Lowest means it will obstruct easier highest means it will exert more force on an object before obstructing Motor Side Left indicates th...

Page 11: ...area and also in a location that it cannot be tampered with by children or pets It is be 3 Connect the two wires form the transformer on the top and bottom screw terminals on the white connector on th...

Page 12: ...use any accessories until setup and programming is complete NOTE If not using safety devices the temporary safety jumper must remain in In order for the gate operator to move Also in order for safety...

Page 13: ...ith the magnet as shown below B on the side of the operator The red limit light should come on when the magnet is lined up 4 After the magnet is lined up move the gate open for programming The open st...

Page 14: ...ere to stop in the open position Manually release and close the gate then lock it into gear This position should be where you want the gate to stop every time Using a screwdriver jump the pins on the...

Page 15: ...Full Open Close Button 1 Choose a button on the remote 2 Press the LEARN button and the LEARN LED will light up 3 Press and hold the button you have chosen for Full Open Close on a remote until the LE...

Page 16: ...power a 24VDC light during the motion of the gate TRAN NOT USED IN THIS APPLICATION PUSH GND Between the push and ground terminal you would put any entry or exit accessory input This would be keypads...

Page 17: ...opener stops If a safety device is not being used in this terminal the operator must have a jumper ran from this terminal to the GND terminal in order to operate Note GDN has the negative power for th...

Page 18: ...f gate opener control board 24V Power Negative or GND or PWR of entry device GND terminal of gate opener control board Push Button Intercoms Normally Open NO or Input INP or Relay of entry device PUSH...

Page 19: ...move safety jumper from PHOTO terminal if using a safety device Magnetic Gate Lock Magnetic gate locks must have their own power supply and their own relay Coil of relay for magnetic lock L1 1 Motor l...

Page 20: ...l digital photos to the technician This is done in your best interest to save unnecessary shipping expenses and time lost Many times we can come up with solutions to issues by seeing pictures that rel...