background image

 

5

 

NOTICE 

The  wall  mount  fasteners  included  with  this  fireplace  are  for  use  ONLY  with  a 
wood-framed  wall  covered  in  drywall  (sheet  rock).  For  concrete  walls,  cinder 
blocks, or other wall types, consult a professional for the best attachment methods. 

 

 

 

ALWAYS  unplug  this  fireplace  heater  before  assembly  or  cleaning,  or  before 
relocating.  
Failure to do so could result in electric shockfire, or personal injury

 

               

 

        

              

 

STEP 2A.

 Locate the wall studs using an electronic stud-finder.   

STEP 2B. The outer screws should go into a wall stud, and the center screw into a drywall anchor.  
STEP 2C. If only one stud is available, the center screw MUST be screwed directly into it, and 
the two outer screws may be screwed into the drywall anchors.  
STEP 2D. Mark the hole locations with a pencil.  The holes should be 8” (20.3 cm) apart, and level.  
The minimum height from the surface below must be 75.2” (191 cm). 

 

 

AVOID INJURY and DAMAGE! The center screw must be screwed directly into a wall 
stud
. The two additional screws may be screwed into the drywall anchors.  

 

                                   

 

STEP 3.  

Drill a pilot hole into each mark using a 1/4” wood drill bit for the drywall anchors, and a 

1/16” wood drill bit for the wall studs.  With a hammer, tap the drywall anchor(s) (C) carefully into 
the hole(s) until they are flush with the drywall surface. Use care to avoid damaging the drywall with 
the hammer.     

 

Drywall 

Studs 

Summary of Contents for EFW-30A

Page 1: ...ead and understand this entire owner s manual including all safety information before plugging in or using this product Failure to do so could result in fire electric shock or serious personal injury CAUTION Keep this owner s manual for future reference If you sell or give this product away make sure this manual accompanies this product ...

Page 2: ...o prevent a possible fire DO NOT block air intakes or exhaust in any manner Doing so could cause a fire DO NOT use on soft surfaces like a bed where openings may become blocked A heater has hot and arcing or sparking parts inside DO NOT use it in areas where gasoline paint or flammable liquids are used or stored Use this heater only as described in this manual Any other use not recommended by the ...

Page 3: ...re or electric shock ONLY use this heater on a 120V AC 15 Amp grounded circuit NEVER overload the circuit If this heater trips the circuit breaker unplug all other appliances on the same circuit before the next use Avoid plugging other appliances into the same circuit as this heater NEVER plug this heater into an outlet that is old cracked or has any loose wires or connections Plugging this heater...

Page 4: ... hammer Wall Mount Installation and Assembly Rear View of Fireplace Step 1 Find a safe location Minimum clearance on each side 19 7 50 cm Minimum clearance below 19 7 50 cm Wall mount only Minimum clearance above 39 4 100 cm Minimum clearance from the front and sides 3 feet 90 cm Choose a location near an outlet so an extension cord is not required DO NOT position the unit directly below a power o...

Page 5: ...only one stud is available the center screw MUST be screwed directly into it and the two outer screws may be screwed into the drywall anchors STEP 2D Mark the hole locations with a pencil The holes should be 8 20 3 cm apart and level The minimum height from the surface below must be 75 2 191 cm AVOID INJURY and DAMAGE The center screw must be screwed directly into a wall stud The two additional sc...

Page 6: ...ng Failure to do so could result in electric shock fire or personal injury NOTE We recommend that two capable adult perform this procedure STEP 5A With the help of a capable adult lift the fireplace and align the two hooks on the back of the fireplace with the slots on the wall bracket Carefully set the hooks into the slots STEP 5B Secure the fireplace to the wall bracket with two M4x8 metal screw...

Page 7: ...Leave no glass pieces where children can find them Failure to do so could cause a choking hazard NOTE We recommend that two capable adult perform this procedure STEP 9A With you or someone holding the glass panel remove the two screws at the top edge of the fireplace with a Phillips screwdriver STEP 9B Together carefully remove the front glass panel and set it aside on a clean soft surface STEP 9C...

Page 8: ...es 2 and 3 Make sure the outlet is in good condition and that the plug is not loose NEVER exceed the maximum amperage for the circuit DO NOT plug other appliances into the same circuit Methods of Operation This electric fireplace can be operated by the CONTROL PANEL located on the right side panel of the fireplace see figure below or by the battery powered REMOTE CONTROL The operation and function...

Page 9: ...h 1h h 4 Press again Timer setting increases by hour until desired setting is reached or until timer turns off 5 Press again to restart timer from h Controls the LED light strips at the left and right edges of the fireplace The LED backlights include individual and alternating color combinations 1 Press once Small indicator lights up Fan blows cool air 750W heater turns on and blows warm air 2 Pre...

Page 10: ...hot air 3 Press again Heaters turn off Fan blows cool air to allow heater to cool down then turns off Press to cycle through the ten Flame Options 1 Press once h light turns on Timer is set to hour 2 Press again 1h light turns on Timer is set to 1 hour 3 Press until desired setting is reached Timer setting increases by hour up to 7 h Examples 3 hours 2h 1h 7 hours 4h 2h 1h h 4 Press again Timer se...

Page 11: ...ocessing center Care and Maintenance Cleaning ALWAYS turn the heater OFF and unplug the power cord from the outlet before cleaning performing maintenance or moving this fireplace Failure to do so could result in electric shock fire or personal injury NEVER immerse in water or spray with water Doing so could result in electric shock fire or personal injury Metal Buff using a soft cloth slightly dam...

Page 12: ...ge caused from tampering with modifying or altering the fireplace insert in any manner Damage due to incorrect assembly improper care misuse or abuse Damage from being used with the wrong power source Water damage Damage caused from this insert being used outdoors Damage caused from this insert being used for excessive periods of time Damage caused by the insert being used in a commercial applicat...