3
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
Keypad Connector Diagram
RED- +Voltage, 27VDC Max
BLACK- Ground
YELLOW- Anti Tailgate
If not used, this must be connected to BLACK.
By adding a door
monitor switch between YELLOW and BLACK, the door will relock
immediately after opening. If the third output is set up as an Internal
Alarm, this switch will trigger the alarm if the door is opened without
a code or if the door is left open longer than the Door Ajar Time
setting.
CONFIGURATION
PINS- “CONFIG”
VOLTAGE SELECT DC ONLY
(Do NOT apply voltage)
12-24V (default), 27VDC Max -
Jumper on 1 pin only
5V- Jumper on both pins
YELLOW- Anti
Tailgate/Internal Alarm
(Do NOT apply voltage)
PINK- Remote Bypass
(Do NOT apply voltage)
BLUE- Common
BROWN- 24-hr Access (Do
NOT apply voltage)
TAN- Earth Ground
BLACK- Ground
ORANGE- Program (Do NOT
apply voltage)
VIOLET- Normally Open
RED- Input Voltage
WHITE- Output A
GREEN- Output B
NOTE: The 2x6 connector is rotated 180 degrees.
CAUTION:
Do NOT run this low voltage wiring in conduit with or
adjacent to line voltage wiring.
GRAY- Normally Closed