Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
10
Configuration
Input Requirements
The SKE Series accepts 5VDC or 12 - 24VDC. System current
draw (max) is as follows:
Standby: 25mA
During Operation: 100mA
Output Capabilities
Main Door output
SPDT relay rated at 24V 2A Max.
Output A
A transistor output intended to drive a relay that can be programmed
for one of the following:
1. CCTV or Light Controller - First key press triggers a Timed Out-
put (1 to 99 seconds).
2. Auxiliary Output - Manual Control or Timed Output (1 to 99 sec-
onds).
3. Second Door - Users can be assigned to open a 2nd door.
4. Doorbell - Press # at the Keypad to trigger a 1 second output for
a doorbell (not included).
Output B
A transistor output intended to drive a relay that can be programmed
for one of the following:
1. CCTV or Light Controller - First key press triggers a Timed Out-
put (1 to 99 seconds).
2. Auxiliary Output - Manual Control or Timed Output (1 to 99 sec-
onds).