Page 12
990-WNWD-I03-020317
Important Installation Notes
1.
The installation must allow access for adequate chimney
sweeping and flue cleaning.
2.
Avoid using bends greater than 45º to the vertical. All flue pipe
sections should be as close to the vertical as possible.
3.
All joints in the flue system must be effectively sealed.
4.
All flue sockets must face upwards. On completing the
installation of the appliance, the chimney, hearth and walls
adjacent to the cooker must conform to local or national
regulations currently in force. In the United Kingdom, the
appropriate sections of the Building Regulations must be
conformed to.
5.
Air inlet grilles should be positioned so that they are not liable to
blockage.
6.
An air extraction device shall not be used in the same
room as the appliance unless adequate additional
ventilation is provided.
7.
A flue cleaning door should be fitted to provide access for
cleaning the flue and chimney.
8.
Check the appliance for soundness of seals between casting
and main components and that all supplied parts and fittings
are correctly fitted.
9.
Ensure the appliance is left operational and hand over the
operating instructions and operating tools supplied.
10.
Before leaving the installation demonstrate the operation of
the appliance to the user. Explain all controls and flue way
access for cleaning.