Page 13
Connection to the power supply
Power supply via 100-240 Vac external adapter
Connect the backup battery to the dedicated input (I in the picture at
page 9).
Connect the external adapter to the specific input (H in the picture at
page 9).
or
12-24 Vdc power supply
Connect the backup battery to the dedicated input (I in the picture at
page 9).
Connect the power supply cable to the +12/24 V and GND terminals (F
in the picture at page 9) taking care to respect the polarity.
Note: the max voltage to be supplied to the +12/24 V terminal is 26
Vdc.
Note: the min voltage required to supply 4GRouter by the 1+12/24 V
terminal is 11 Vdc.
Note: a protection cut-out switch must be installed upstream to
interrupt power supply in case of fault.
Turning 4GRouter on
Power 4GRouter.
Wait 45 seconds after power-up to give time to 4GRouter to register
correctly with the 4G LTE/UMTS/GSM network.
Make sure the red LED (device status) flashes briefly once every 3
seconds as shown in chapter “Signals” (see page 55).
If the red LED flashes quicker and stays lit for a longer time 4GRouter has not
properly registered with the 4G LTE/UMTS/GSM provider:
Disconnect 4GRouter and make sure the SIM card is inserted correctly
and that the PIN is not locking it.
See chapter “Problem-detection guide” (page 58).