ii.
Wiring Fault
When connected to an incorrectly wired branch circuit outlet, in addition to
the illumination of the Red LED, the LCD Event Monitor will display the
following information:
iii.
Abnormal Voltage
When the magnitude of the branch circuit outlet voltage is not acceptable*,
the Filter will disconnect power to its outlets and display the following
information on the LCD Event Monitor (*above the over-voltage shutdown
threshold or below the under-voltage shutdown threshold; refer to Section
IV: Diagnostic Software for more information):
Wiring Fault Condition
Display
Example Display
Line (Hot) / Neutral
Reversed
(120V products only)
rP (Reverse
Polarity)
Missing Ground
gnd (no Ground)
Voltage Condition
Display
Example Display
Over-Voltage
OFF + ▲ + Voltage
Under-Voltage
OFF + ▼ + Voltage