![ESI IVX 20 Installation Manual Download Page 50](http://html1.mh-extra.com/html/esi/ivx-20/ivx-20_installation-manual_2426951050.webp)
Function 5: Voice mail programming
IVX 20
H.2
The sequence of programming is as follows:
1.
CO line access
— Input the CO line group (9, 8, or 7) that is to be accessed for paging.
2.
Dialing pause
— Input the pause in seconds that is to occur after the pager numbered has been
dialed and before the mailbox number is to be dialed.
Range:
0–20 seconds.
Default:
6 seconds.
3.
Paging interval
— Input the number of minutes for the interval between reminder pages. 0 for
no reminder pages (i.e., page once at the first new message).
Range:
10–1,440 minutes.
Default:
30 minutes.
Message length
On the IVX 20 system, maximum voice message length is 60 minutes.
.