background image

10

OPERATION 

VICTORY-LX 3 LEG ELECTRIC TABLE BASE

CHANGING THE HEIGHT DISPLAY UNITS 

This function allows you to change the display units from 
centimeters to inches or the other way around. 
• Press and hold 

S

, then press and hold the DOWN   button. 

Continue to press both buttons for about 3 seconds.
—  The height information will change between centimeters 

and inches.

• Release both buttons.

RESET THE CONTROL UNIT TO FACTORY SETTINGS 

To reset the control unit to factory settings, re-initialize the table.
• Press and hold  the UP   and DOWN  buttons simultaneously 

for more than 3 seconds. 
—  The legs will begin to move down at half speed of normal 

operation.

• Continue to press  the UP   and DOWN  buttons. 

—  The legs will move down to the lowest position, then 

rebound 

1

/

16

" to 

3

/

16

" (2mm to 5mm) and stop.

• Release the UP   and DOWN  buttons at the same time. This 

completes the initialization procedure.

If one or more motors are changed 

in a system, the control unit must be 

reset to factory settings.

ADUSTING THE DIGITAL KEYPAD READOUT

This function allows you to change the readout of the digital display.
• Verify the display unit format (inches or mm), set the table to any height, measure the actual height, and 

   write down the number (inches or mm).   

• Press and hold the 

S

 button. Then press and hold the     button for about 3 seconds until the first number on

   the digital display flashes.

• Release the buttons then press     or     to change the first number you measured.

• Press the 

button agin. The 2nd number on the digital display flashes.

• Press     or     to change the 2nd number you measured.

• Press the 

button again.  The 3rd number on the digital display flashes.

• Press     or     to change the 3rd number you measured.

• Press the 

button to complete the operation.

    

Summary of Contents for 3V-LX-C3636-24 Series

Page 1: ...VICTORY LX Model 3V LX C4848 24 ___ Model 3V LX C4848 30 ___ Model 3V LX C4836 24 ___ Model 3V LX C4836 30 ___ Model 3V LX C3636 24 ___ Model 3V LX C3636 30 ___ ___ SLV BLK or WHT 3 LEG ELECTRIC TABLE...

Page 2: ...trations show 90 tables 120 tables are illustrated only to show the difference in attachment to the center leg brackets CAUTION Always check that screws used to attach components to the work surface a...

Page 3: ...d top supports as shown below Positioning does not need to be exact at this time The longer cross channels are toward the rear of the table The longer sections of the cross channels are toward the sid...

Page 4: ...loosen all 16 set screws on the inward side of the cross channels Position the outer leg columns and top supports so that the outer top supports are approximately 1 25mm from the ends of the table an...

Page 5: ...nd brackets see illustration Use a 5mm Allen key to secure the screws STEP 8 Attach the feet to the outer leg columns Place the square opening on the foot over the leg The shorter side of the foot sho...

Page 6: ...e the rear cross channels will be 6 from the rear of the table With feet for a 30 deep table the rear cross channels will be 9 from the rear of the table STEP 10 Attach all three top supports to the t...

Page 7: ...ntrol unit near the back of the table on the same side as the digital keypad Be sure that the cable from the keypad can reach the control unit and the motor cables can extend from the control unit to...

Page 8: ...of normal operation Continue to press the UP and DOWN buttons The legs will move down to the lowest position then rebound 1 16 to 3 16 2mm to 5mm and stop Release the UP and DOWN buttons at the same t...

Page 9: ...ides 26 total STEP 19 IMPORTANT There must be 1 25mm of clearance on all sides of the work surface and other moving parts to ensure free unobstructed movement Adjust the leveling glides on the feet to...

Page 10: ...t the minimum height of the table Raise or lower the table to the desired minimum height Press and hold S then press and hold 1 Continue to press both buttons for about 3 seconds The letter L appears...

Page 11: ...3 16 2mm to 5mm and stop Release the UP and DOWN buttons at the same time This completes the initialization procedure If one or more motors are changed in a system the control unit must be reset to f...