52 

6.6 – Warranty 

Warrant conditions are set out in the Escort Data Loggers’ current Terms and Conditions. Below 
please find the wording as per version TCEDLSINT042. This is, however, not binding and the 
current Terms and Conditions will prevail over the details given here.  

 

Product Warranty period is 24 months (excluding batteries). 
 
Warranty does not cover: 
 

- Loss of use or consequential loss, 
-  Calibration if the unit has been subject to environmental conditions 

 

outside the specified ones 

 

- Willful damage, mistreatment, misuse or abuse of the product, 

 

- Loss or damage caused by the ingress of moisture, unless ordered with 

 

immersion rating, 

 

- Batteries, 

 

-  Circumstances where the unit has been modified from manufacturers 

 

specifications, 

 

-  Exposure of the REDi  to temperatures outside the specified storage 

 

temperature (-40ºC to 85ºC (-40ºF to 185ºF), 
- Exposure of the REDi to environmental conditions outside those deemed 
acceptable by EDLS 

 

 

In case of a warranty claim Escort Data Loggers will repair the goods or supply 
an equivalent replacement. 
 
In some circumstances, where a specific return was authorized,  Escort Data 
Loggers may permit the use of its Federal Express account for returning goods. 
Such permission is valid ONLY for the authorized shipment. Escort Data Loggers 
will  not accept any freight charges for goods that have been returned without 
Escort Data Loggers’ s expressed permission. 
 
Customers and distributors may return product to us for accuracy testing, if they 
have doubts as to the product’s overall accuracy: 
 

-  If the product is returned within the warranty period, a Traceability 

 

certification will be performed, and a certificate issued. 

 

-  If the REDi  does not pass the certification, i.e. the REDi  is at fault, the 

 

REDi  will be replaced or repaired as per the warranty conditions  and no 

 

charges (other than freight charges) will apply. The new REDi will   be 

 

issued with a Traceability certificate free of charge. 

 

-  If  the  REDi  reads  within the specifications, a Traceability certificate 

 

will be issued and you will be charged for this service. 

 

-  If the product is returned outside the warranty period, a Traceability 

 

certificate will be issued and charged regardless of the outcome of the  

 

test. 

 

-  Escort Data Loggers  will not pay for any performance tests undertaken 

by any outside organization without prior approval. 

Summary of Contents for EA-RI-8

Page 1: ... Wireless Receiver EA RI 8 and EA RI 9 User Manual Thank you for purchasing an ESCORT Product Please read this user manual before using this product www escortdataloggers com ESCORT Data Loggers 2011 Version 1 01 ...

Page 2: ... Bookmarked Readings using your REDi 23 3 2 8 Locate a wireless logger using your REDi 24 3 2 9 Sending a bookmark command from your REDi to a wireless logger 25 3 2 10 Restarting a Wireless logger using your REDi 26 3 3 Transferring Data to your PC 27 4 System options 28 4 1 Shut Down 28 4 2 Auto off 28 4 3 Backlight 29 4 4 Available Memory 29 4 5 Rechargeable Batteries 30 4 6 Temperature Unit Co...

Page 3: ...battery life of wireless loggers 46 6 2 Successful REDi to Wireless Communication 47 6 3 Recharging your REDi 48 6 3 1 Attempting to charge faulty or non rechargeable batteries 49 6 4 Specifications 50 6 4 1 Storage Database 50 6 4 2 Readout 50 6 4 3 Power Supply 50 6 4 4 Processor 50 6 4 5 Communication 50 6 4 6 Communication Frequency 50 6 4 7 Keyboard 50 6 4 8 Other Features 50 6 4 9 User Softw...

Page 4: ...use your REDi device to malfunction or result in personal injury d If your REDi device is not to be used for prolonged periods of time remove the batteries to prevent loss of battery life and possible battery leakages that may damage the device e Force should never be applied to this device f Your REDi device should only be operated within the parameters specified within this manual g Never attemp...

Page 5: ...nd contains a large liquid crystal display 160 x 160 bitmap and 7 key keyboards A communications connector which allows the REDi to be connected to a PC is supplied with the unit and can be mounted at the top of the unit The REDi is menu based To trigger actions and display data the user must select a menu item by using the up down arrow keys to move a highlight bar over that option then select it...

Page 6: ...6 1 3 Package Contents Your REDi package contains the following items 1x REDi Device 1x Serial port connector 1x REDi user manual 2x AA batteries re chargeable ...

Page 7: ...tton 6 Interface Connector 3 Escape button Esc 7 Antenna side view 4 Power button 8 Battery compartment Message text Loggers connected to Status bar Loggers downloaded with scrolling OK option Option Selected Option Time Connected to 10 loggers 9 10 read Read new Read all View data System Options 15 54 ...

Page 8: ...ewdriver to remove these Insert the two batteries with the correct polarity as marked inside the compartment Before replacing the lid ensure that the batteries are fully inserted If the batteries are not inserted correctly the lid will not fit properly and could consequently damage the seal or the batteries Carefully place the cover of the battery compartment back on and gently tighten the three s...

Page 9: ...e down via the menu screens you can do so by selecting System Options and then Shut Down see figure 2 2 For information regarding REDi s AutoOff function refer to chapter 4 System Options of the REDi user manual Press the power button to turn on and or off Figure 2 1 REDi Power Button Figure 2 2 REDi Shut Down Screenshots Your REDi will switch on automatically when it is connected to a serial port...

Page 10: ...function enabled but you have not assigned a password using ESCORT Console the default password is 0000 see figure 2 3 Once a password has been assigned to your REDi device a screen will be displayed upon start up that prompts users to enter their password see figure 2 3 Figure 2 3 Enter Password Screenshot To enter your password use the up and down arrow keys on the key pad to change the numbers ...

Page 11: ...digit password as per the instructions above Figure 2 5 Invalid Password screenshot Once the correct password has been entered your REDi device will proceed to the System Info see chapter 4 7 and after that automatically to the Main Menu see figure 2 6 You will then be able to access all of the menus and functions that your REDi device offers Figure 2 6 REDi Main Screen ENTER CODE 0 INVALID Read n...

Page 12: ... configure its date and time to your PC s date and time This takes place when using either the program and configure or the download function in ESCORT Console 2 5 Downloading Software In order to access your REDi using your PC you need to download ESCORT Console software from the Escort Data Loggers website www escortdataloggers com ESCORT Console software is free to download and use ...

Page 13: ...ch follows the System Info see 4 7 after initiating your REDi device and allows for two download options Read New and Read All 3 1 1 Read New The Read New option allows you to locate and download loggers that have not previously been downloaded by a specific REDi unit The highlight bar automatically defaults to the first option Read new on the main menu If you select Read New and press OK the next...

Page 14: ...nicating distance The Read All option is located on the Main Menu screen and is option number two To download the entire available logger data select Read All and press OK The next screen displayed is the search screen followed by the connected to loggers screen see figure 3 2 Once the REDi has downloaded all of the found logger information you are given the option to either view the recently down...

Page 15: ...t Read all If those missing loggers have not been downloaded before use the Read new function 3 2 Viewing and Interpreting Data Your REDi device is designed to provide several different ways in which to view the logger data that has been downloaded into its memory There are two ways in which you can access logger data from the REDi s memory Firstly you can access data saved from previous download ...

Page 16: ... summary or out of specification information 3 2 1 View Recent The View Recent option will only display data which has been collected during the REDi s most recent scan see figure 3 6 To scroll through the different loggers first the Number of Loggers in Memory window see figure 3 8 must be highlighted By pressing the left and right arrow keys on the key pad you can move through the logger list Fo...

Page 17: ... 7 No Loggers screen If your REDi registers recently downloaded data within its memory your REDi screen will display the basic information relating to that logger data Overview Items such as product code serial number battery status and whether the logger has logged readings out of specification see figure 3 8 No loggers 0 0 Exit 15 54 View recent View all Exit 15 54 MI IN D 2 LR8 MI BF 053 001 CO...

Page 18: ...h the different loggers first highlight the Number of Loggers in Memory window By pressing the left and right arrow keys on the key pad you will be able to move through the logger list For an explanation regarding the viewing of detailed logger information please refer to 3 2 3 View Summary and 3 2 4 View out of Specification Figure 3 9 View All and Overview View recent View all Exit 15 54 MI IN D...

Page 19: ...LOW Battery status Time Zone GMT 13 00 Time zone Sampling 2 min Sampling rate Readings 1868 Number of readings taken Start Time Starting Time 11 04 05 11 20 End Time Finishing time 14 04 05 01 34 Active 40 70ºC Temperature where active High Spec 32 0ºC High alarm temperature Low Spec 6 5ºC Low alarm temperature Max 56 0 º C Maximum temperature reached Avg 14 0 º C Average temperature reached Min 2...

Page 20: ...an choose to look at another logger s data file that is saved in your REDi memory see figure 3 12 You also get there by pressing the Esc button Figure 3 12 Return to Overview Min 20 5ºC Alarm None Time over 32 0ºC 17 32 00 Time under 6 5ºC 23 12 00 State Stopped View new logger Exit 15 54 MI IN D 2 LR8 MI BF 053 001 CONTAINER 4 Battery LOW Stopped FAIL 5 10 View Summary View Out Spec Restart Logge...

Page 21: ...pecification readings Once you have chosen the View Out Spec option a list of readings does appear on your REDi screen You can view all of the readings by selecting the Next option located at the top and bottom of the Out of Specification screen If you would like to exit this screen simply press the escape key Esc located at the bottom right of your REDi keypad after which you will be returned to ...

Page 22: ... displays a warning message and the option to abort or continue see figure 3 16 Note When you clear your loggers alarm a bookmark will automatically be recorded in your logger s memory and can be viewed via your REDi or once downloaded using ESCORT Console software Figure 3 16 Clear Alarms screen Next 13 01 13 16 43 Reading 41 5ºC 13 01 13 16 44 Reading 41 5ºC 13 01 13 16 45 Reading 42 0ºC 13 01 1...

Page 23: ...kmarks via your REDi device or via ESCORT Console software Once a logger with the bookmark feature has been downloaded the appropriate menu option will appear on your REDi s display see figure 3 16 To view your bookmarked readings select the view bookmarks menu option Once selected a list of bookmarked readings will appear together with the date and time that the reading was recorded To exit the b...

Page 24: ...ger using your REDi first find the logger s serial number via either the Read All or Read New menu options Once you have located the logger s details scroll down the menu options until you locate the Find Logger menu option and click OK Once selected a new screen will appear which displays a warning message see figure 3 19 Figure 3 19 Find Logger screen MI IN D 2 LR8 MI BG 053 001 CONTAINER 4 Batt...

Page 25: ... located the logger s details scroll down the menu options until you locate the Set bookmark menu option and click OK Your REDi will then display the message Contacting plus the logger s serial number Once your REDi has made contact with your chosen logger your REDi will display a confirmation message click the OK button see figure 3 20 Figure 3 20 Set bookmark screen MI IN D 2 LR8 MI BG 053 001 C...

Page 26: ...ddition the Restart function restarts your logger immediately The logger will show d for start delay or the latest reading if no delay was specified This function is not available if the program of the logger has been password protected or if the logger is a single trip logger With regard to a password protected logger you are required to connect the logger to ESCORT Console for re arming and supp...

Page 27: ...Console software from the Internet or from CD on your PC and follow the instructions regarding the use of the software see chapter 5 To ensure the REDi device can successfully communicate with the software connect the interface cable see figure 3 17 to a serial communication port COM port DB9 on your PC Figure 3 17 Serial port connector ...

Page 28: ...ption is highlighted see figure 4 1 You can also shut your REDi device down by pressing the power key located at the bottom left of your REDi keypad at any time 4 2 Auto off The Auto Off option is the second option your REDi device displays in the System Options screen see figure 4 2 This option allows you to set an automatic shut down time if no key has been pressed for a certain amount of time Y...

Page 29: ...ly you can set your required backlight time frame using ESCORT Console software for more information regarding this refer to chapter 5 of this user manual Figure 4 1 Backlight Option 4 4 Available Memory The Mem left option is the fourth option in the System Options screen see figure 4 4 This is a read only option and displays your REDi s available memory space in kilobytes Shut Down AutoOff 30 mi...

Page 30: ...lays in the System Options screen see figure 4 5 This option allows you to set the temperature unit to either ºC or ºF You change between the two temperature units by using the left and right arrow keys on the REDi keypad Alternatively you can set your required temperature unit using ESCORT Console software for more information regarding this refer to Chapter 5 of this user manual Figure 4 5 Tempe...

Page 31: ... This blockade was implemented as a safety lock to prevent users from accidentally erasing important data In these instances you can only delete data blocks from the REDi via ESCORT Console software Figure 4 6 Erase all data 4 8 System Information The System info option is the eighth option your REDi device displays in the System Options screen see figure 4 8 This screen displays general informati...

Page 32: ...9 Figure 4 9 Exit to Main Menu from System Options Read new Read all View data System Options 15 54 Shut Down AutoOff 30 min Backlight 10 s Mem left 988k Rechargeable Y Temp Unit ºC Erase all data System info Exit 15 54 Shut Down AutoOff 30 min Backlight 10 s Mem left 988k Rechargeable Y Temp UnitºC Erase all data System info Exit 15 54 ESCORT REDi REDi F W 1 1h Batt 2 83 P N EA RI 9 S N 0515 1234...

Page 33: ...port you can use a USB to serial port adapter available from your local electronics store to create a COM port Please follow the installation instructions supplied with the adapter You can download ESCORT Console from the ESCORT DL website on the Internet http www escortdataloggers com Alternatively you can purchase the ESCORT Console software CD Product code JA SWP CON through your local distribu...

Page 34: ...stalled you can open the software by clicking on the ESCORT icon on your desktop or selecting ESCORT Console from All Programs in the Start menu Figure 5 2 Opening ESCORT Console software In ESCORT Console you can choose both the COM port the software uses for communication with your REDi and loggers as well as the products you are using In the Edit menu choose the Options command and then go to t...

Page 35: ... Configure command from the Action menu or click on the Program and Configure icon Figure 5 4 Configure wizard Please follow the instructions on the screen of the Configuration Wizard to proceed to the Search screen Make sure your REDi is switched on when trying to communicate to the unit The REDi will show a double arrow at the bottom of the current screen while it is communicating with ESCORT Co...

Page 36: ...ure 5 6 Password input 5 4 2 Description After clicking Next on the Search screen you can view and adjust the configuration of your REDi unit The description can be up to 42 characters long consisting of numbers and letters Simply type the desired description for this unit in the Description field This information will show within the System Information of the unit and on the Search screen in Cons...

Page 37: ...assword and Confirmation fields In addition you have the option to turn the password protection on or off by selecting the Restrict Access tick box see figure 5 8 Figure 5 8 Password Settings window 5 4 4 Temperature Scale Below the Description field in the Program and Configure window there is a drop down box allowing you to select the temperature scale Simply select the scale that you would pref...

Page 38: ... day of the month e g 10 for the 10th day of the month Figure 5 10 Date Format drop down menu 5 4 6 Time Format The Time Format drop down box is located under the Date Format drop down box This is where you format your REDi s date and time functions You will use this feature to display the time of events or readings as well as the clock of the REDi A sample of the current time in the selected form...

Page 39: ...ease use the sliding control to adjust the auto off time the time in minutes is displayed on the right hand side The auto off time can be between 2 and 30 minutes Figure 5 12 Auto off control 5 4 8 Backlight On Time The Backlight On Time control configures for how long the screen LCD of the REDi will be lit after a key is pressed Backlight helps you see the data on the screen in the dark You can c...

Page 40: ...rrently stored in your REDi unit Before you tick this option make sure that the logger data currently in the memory is no longer used or has been downloaded to a PC and saved If you select the tick box next to Delete all the data blocks from within the REDi the whole memory will be reset and all logger data is deleted This action cannot be reversed 5 4 11 Summary After selecting the Next button on...

Page 41: ...wnload the logger data stored in your REDi memory to a PC This is made possible via the Download Readings wizard In addition the Download Readings wizard offers you the option to delete all data blocks from your REDi s memory To download the data blocks choose the Download command from the Action menu or click on the Download icon which is located on the task bar below the action menu ...

Page 42: ...ssword protected units please follow the instructions described in chapter 5 4 1 5 5 1 Selecting Logger Data for Download Once the Download Readings wizard has located your REDi device via one of your PC s available ports COM and or USB the Download readings wizard will display a REDi icon the logger files ready for download and a series of tick boxes With a full REDi memory 162 logger files it ma...

Page 43: ... been password protected against download you will be asked to supply the password You cannot download protected data without entering the correct password If the password has been lost the logger has to be returned to your ESCORT distributor for password reset 5 5 3 Logger Properties Logger data with a cross in the tick box next to the logger information cannot be downloaded You can however view ...

Page 44: ...e figure 5 18 Figure 5 18 Download data from REDi For more details on analysing logger data using ESCORT Console software please refer to the Help file located under the help dropdown menu of the menu bar 5 5 5 Deleting Logger Data Blocks You have the ability to delete all logger files currently stored in your REDi once they have all been downloaded To perform this function simply select the Delet...

Page 45: ...ase ensure that you save the files displayed in ESCORT Console as the data cannot be retrieved once it has been deleted from the REDi see figure 5 19 Figure 5 19 Downloading all logger data and deleting all data blocks ...

Page 46: ...acity At the completion of the charge cycle the charger switches to trickle charge In this state the battery symbol will flash once every 20 seconds Under normal operation conditions with a fresh battery no symbol is shown Figure 6 1 Low battery Figure 6 2 High battery 6 1 2 Prolonging the battery life of wireless loggers In a communication system one device must initiate communications by sending...

Page 47: ...antennae should be pointing in a horizontal position and free of interference There should be at least 0 5m of free space around the antenna in all directions The Wireless loggers should be securely attached to the outside of the package that it is being shipped with The package should be secured so that it cannot move during the course of its transportation as that might result in damage to the l...

Page 48: ...e no longer than four hours to complete The battery status icon located in the bottom right corner of your REDi s screen will be initiated and will fill in black from right to left see figure 6 3 If the battery symbol does not appear or appears but disappears quickly either your REDi batteries have been sufficiently charged or the polarity of your AC Adaptor is incorrect The REDi uses a fast charg...

Page 49: ... If an attempt is made to recharge non rechargeable batteries the REDi will display the following image in the top right of its LCD display see image 6 4 below This image is also displayed if there are no batteries in the unit or the batteries within the unit are faulty see power supply specifications in section 6 4 3 Figure 6 4 Incorrect faulty or absent battery symbol OFF ...

Page 50: ...uilt 3hour NiCd Charger 6 4 4 Processor Mitsubishi M16 20K RAM 128k ROM 6 4 5 Communication Between REDi and PC RS232 as 9600 baud Between REDi and Logger Radio Communication 83Kbaud roughly 2 5KB per second transfer rate 6 4 6 Communication Frequency EA RI 8 at 868 35 MHZ European standard also for South Africa EA RI 9 at 916 5 MHZ American standard also for Oceania and Asia 6 4 7 Keyboard 7 Mech...

Page 51: ...d used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or...

Page 52: ...re a specific return was authorized Escort Data Loggers may permit the use of its Federal Express account for returning goods Such permission is valid ONLY for the authorized shipment Escort Data Loggers will not accept any freight charges for goods that have been returned without Escort Data Loggers s expressed permission Customers and distributors may return product to us for accuracy testing if...

Page 53: ...N 301 489 3 V1 4 1 2002 8 FCC Identifier TZH REDI Name of Grantee Escort Data Loggers Equipment Class Part 15 Low Power Transceiver Rx Verified FCC Rule Parts 15C Frequency Range 916 05 916 05MHZ Authorised Master Manual for Escort Data Loggers Reference ISO 9001 2008 Revision 1 page 1 1 ISO 9001 2008 ...

Page 54: ...e kindly ask you to adhere to national policies and regulations concerning waste disposal and recycling Wireless Mini loggers and REDi devices must not be placed in your household rubbish European Standard EN 50419 2005 If you have any questions please do not hesitate to ask at your nearest electronics shop or send an e mail to techsupport escortdataloggers com Thank you for your understanding ...

Reviews: