GD350A series high-performance multifunction VFD
-183-
Function
code
Name
Description
Default Modify
enter the interface.
Note:
Restoring the default values may delete
the user password. Exercise caution when
using this function.
P07.01
Reserved
P07.02
Key function
selection
Range: 0x00–0x27
Ones place: Function of QUICK/JOG
0: No function
1: Jog
2: Reserved
3: Switch between forward and reverse
rotating
4: Clear the UP/DOWN setting
5: Coast to stop
6: Switch command channels in sequence
7: Reserved
Tens place: Reserved
0x01
◎
P07.03
Sequence of
switching running-
command channels
by pressing QUICK
When P07.02=6, set the sequence of
switching running-command channels by
pressing this key.
0: Keypad→Terminal→Communication
1: Keypad←→Terminal
2:
Keypad←→Communication
3: Terminal
←→Communication
0
○
P07.04
Stop function
validity of
STOP/RST
The function code specifies the stop function
validity of STOP/RST. For fault reset,
STOP/RST is valid in any conditions.
0: Valid only for keypad control
1: Valid both for keypad and terminal control
2: Valid both for keypad and communication
control
3: Valid for all control modes
0
○
P07.05–
P07.07
Reserved
P07.08
Frequency display
coefficient
0.01–10.00
Display frequency = Running frequency *
1.00
○