Combustion Air
Flow Error
•
Check whether the pressure switch is activating at startup (there is an
orange indicator LED in the control tray). If not check the pressure switch
electrical connection is correct.
•
Check that the hoses are connected at both ends. Ensure the hoses are not
kinked.
•
Ensure the pressure switch is mounted vertically and the diaphragm is op-
erational. The grey hose should be connect to the low pressure port and the
translucent to the high pressure port
•
Check that both flues are securely connected at both ends to the appliance
and the powerflue wall terminal and that the flue is not damaged
(DX Only) Duct
Overtemp
The hot air duct temperature sensor has detected excessive heat at the duct
outlet.
•
Ensure that there are at least TWO air vents installed and open in the same
room as the fireplace
•
Ensure the duct fan is operating when the fireplace is running. If not check
that the duct fan cord is plugged into the fireplace.
11. Power Failure
In the event of power failure the fire will immediately shutdown and the gas valves will automatically
close. If the remote was turned off after the power cut then the fire will return to standby mode once the
electrical supply is restored until its next use. If however the remote was left in the on mode then the fire
will relight within a few minutes of the electrical supply being restored.