background image

1. 

Remote Control Layout 

C

SET

FAN

BOOST

FLAME

EFFECT

ONLY

Room and Set

temperature

display

Room or Set

temperature indicator
Low battery

indicator

Flame Effect

indicator

Fan Boost indicator

Timer Indicator
Clock adjust indicator

Active timer indicator

Timer On / Off time indicator

Hour and minute

display

Time & timer AM/PM indicator

TIM

ER

SEL

ECT

ACT

IVA

TE

TIM

ER

SET TIME

1

2

3

4

5

6

7

8

9

Display

 

Shows temperature settings and 

status of timers and other functions

On / Off

 

Switches the appliance on and off.

Flame Effect

 

Places the fire in a constant low 

output mode.

Minus

 

Adjusts the temperature and time 

settings down. NOTE: The fan will 

operate at its lowest settings.

Fan Boost

 

Puts the fan into a high output mode.

Plus

 

Adjusts the temperature and time 

settings up.

Activate Timer

 

Enables the timers.

Key Lock

 

Enables and disables the remotes key lock

3+7

Timer Select

 

Allows you to program in advance 

the times you wish to automatically 

turn the fire on and off.

Set Time

 

Allows you to set the clock.

Summary of Contents for DL-Series

Page 1: ...User Guide For the latest documentation visit www escea com 630160_8 DX Series DL Series Gas Fireplace...

Page 2: ...RE USE AND SERVICED AT LEAST ANNUALLY BY AN AUTHORISED TECHNICIAN THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER S WRITTEN INSTRUCTIONS THIS APPLIANCE IS NOT INTENDED FOR USE BY...

Page 3: ...e 05 4 Keylock 06 5 Timer Operation 06 Activate Timer De activate Timer 6 Auxiliary On Off Button 07 7 Over Temp Shutoff Operation 07 8 Sound and Smell 08 Sounds Fan Gas Control Valve Appliance Metalw...

Page 4: ...Shows temperature settings and status of timers and other functions On Off Switches the appliance on and off Flame Effect Places the fire in a constant low output mode Minus Adjusts the temperature a...

Page 5: ...oost DL Series ONLY The fire has four FAN SPEED settings The first low fan speed will run automatically on start up The second and third fan speed will automatically switch on or off with the increase...

Page 6: ...r MINUS 4 button will change the hour Pressing the TIMER SELECT button 5 again will make the minute figures start flashing You will continue to see the ON and the number 1 This indicates that you are...

Page 7: ...erature This is referred to as the Overtemp Shut Off Mode To enable Overtemp Shut Off Mode so the fire will turn off the main burner when the Room tempera ture climbs above the Set temperature you nee...

Page 8: ...he fire is switched off after being run for a while there may be popping and fluttering noises as the residual gas in the burner burns away These are normal and should be no cause for concern Applianc...

Page 9: ...rotective film over the fascia the entire fascia will need to be wiped to avoid seeing a difference in surface texture Ensure this film is distributed evenly 4 If the film is applied too heavily and i...

Page 10: ...e order and test run heater 10 Trouble shooting Escea gas fires communicate both to and from the fire and remote This enables the remote to provide some basic fault finding information that is useful...

Page 11: ...in restricted air flow at the top of the fire Room air fans may be slowed or stalled Remove firebox check that fans are plugged in cleaned and free turning The gas regulator being set too high resulti...

Page 12: ...l and that the flue is not damaged DX Only Duct Overtemp The hot air duct temperature sensor has detected excessive heat at the duct outlet Ensure that there are at least TWO air vents installed and o...

Reviews: