background image

9. 

Fascia, Log and Glass care

The Fascia is the visible surround of your Escea Gas Fireplace and must be treated carefully to prevent 

unsightly marks from tarnishing the visual quality of the product. Some marking over time is inevitable 

however, so the following directions will assist you in getting the maximum enjoyment from your Escea 

Gas Fireplace.

NEVER, EVER RUB THE FASCIA.

The outside of an Escea Fascia must only be cleaned with a soft microfibre cloth. If heavier cleaning is re-

quired for the likes of grease or stubborn fingerprint removal we recommend the use of Steel Kleen brand 

Ezi Wipes. These wipes have been tested by Escea technicians and produce very satisfying results, when 

used correctly. Instructions for their use follow.

For Powder Coated Fascias:

1. 

Ensure that the Gas Fireplace is off, and that the fascia is cold to the touch.

2. 

Using the gloves provided with your fascia, remove the towelette from the sachet and wipe the  

 

fascia with even, straight strokes.

3. 

Because the wipe leaves a protective film over the fascia, the entire fascia will need to be wiped  

 

to avoid seeing a difference in surface texture. Ensure this film is distributed evenly.

4. 

If the film is applied too heavily and is quite visible, you can remove the excess by gently wiping  

 

dry with a microfibre cloth 

5. 

Ensure that no film is applied to the glass of your Escea Gas Fireplace. If applied accidentally,  

 

wipe off with an absorbent microfibre cloth.

Cleaning the logs / Glass (DL series):

Step 1:

   If using a Velo or Rado fascia, Remove the lower trim which is  

 

held in place by magnets

Step 2:

   Lift off the inner fascia by unscrewing the base of the inner  

 

fascia, then pulling it out and lifting it up and off.

Step 3:  

Unscrew the top and side glass retainers and remove them.  

 

Take care that the glass does not fall forwards at this stage.

Step 4:  

Lift out glass and place it carefully aside.

Step 5:  

Take out log set and gently brush any soot from log with a  

 

soft hearth brush. The burner tops can be vacuumed too.

Step 6:

   Clean the inside and outside of glass with normal glass    

 

cleaning products. Use a clean dry cloth only. Stubborn marks  

 

may be cleaned with a ceramic glass cleaner.

Step 7 :  

Replace in opposite order and test run heater.

Step 2

Summary of Contents for DL-Series

Page 1: ...User Guide For the latest documentation visit www escea com 630160_8 DX Series DL Series Gas Fireplace...

Page 2: ...RE USE AND SERVICED AT LEAST ANNUALLY BY AN AUTHORISED TECHNICIAN THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER S WRITTEN INSTRUCTIONS THIS APPLIANCE IS NOT INTENDED FOR USE BY...

Page 3: ...e 05 4 Keylock 06 5 Timer Operation 06 Activate Timer De activate Timer 6 Auxiliary On Off Button 07 7 Over Temp Shutoff Operation 07 8 Sound and Smell 08 Sounds Fan Gas Control Valve Appliance Metalw...

Page 4: ...Shows temperature settings and status of timers and other functions On Off Switches the appliance on and off Flame Effect Places the fire in a constant low output mode Minus Adjusts the temperature a...

Page 5: ...oost DL Series ONLY The fire has four FAN SPEED settings The first low fan speed will run automatically on start up The second and third fan speed will automatically switch on or off with the increase...

Page 6: ...r MINUS 4 button will change the hour Pressing the TIMER SELECT button 5 again will make the minute figures start flashing You will continue to see the ON and the number 1 This indicates that you are...

Page 7: ...erature This is referred to as the Overtemp Shut Off Mode To enable Overtemp Shut Off Mode so the fire will turn off the main burner when the Room tempera ture climbs above the Set temperature you nee...

Page 8: ...he fire is switched off after being run for a while there may be popping and fluttering noises as the residual gas in the burner burns away These are normal and should be no cause for concern Applianc...

Page 9: ...rotective film over the fascia the entire fascia will need to be wiped to avoid seeing a difference in surface texture Ensure this film is distributed evenly 4 If the film is applied too heavily and i...

Page 10: ...e order and test run heater 10 Trouble shooting Escea gas fires communicate both to and from the fire and remote This enables the remote to provide some basic fault finding information that is useful...

Page 11: ...in restricted air flow at the top of the fire Room air fans may be slowed or stalled Remove firebox check that fans are plugged in cleaned and free turning The gas regulator being set too high resulti...

Page 12: ...l and that the flue is not damaged DX Only Duct Overtemp The hot air duct temperature sensor has detected excessive heat at the duct outlet Ensure that there are at least TWO air vents installed and o...