background image

User Manual

esatto.house

 6

7

Safety Warnings (Continued)

•  This appliance can be used by children aged from  

8 years and above and persons with reduced 
physical, sensory or mental capabilities or lack of 
experience and knowledge if they have been given 
supervision or instruction concerning use of the 
appliance in a safe way and understand the hazards 
involved. Children shall not play with the appliance. 
Cleaning and user maintenance shall not be made 
by children without supervision (be applicable for 
the European Countries ).

•  This appliance is not intended for use by persons 

(including children) with reduced physical, sensory 
or mental capabilities or lack of experience and 
knowledge, unless they have been given supervision 
or instruction concerning use of the appliance by a 
person responsible for their safety. (be applicable 
for other countries except the European Countries )

•  Children should be supervised to ensure that they 

do not play with the appliance.

•  If the supply cord is damaged, it must be replaced 

by the manufacturer, its service agent or similarly 
qualified persons in order to avoid a hazard.

•  The appliance shall be installed in accordance with 

national wiring regulations

•  Do not operate your air conditioner in a wet room 

such as a bathroom or laundry room.

•  The appliance with electric heater shall have at 

least 1 meter space to the combustible materials.

•  Contact the authorised service technician for repair 

or maintenance of this unit.

•  Contact the authorised installer for installation of 

this unit.

•  When there are wide differences between  

“USER’S MANUAL and “Remote controller 
Illustration” on function description, the description 
on “USER’S MANUAL” shall prevail.

•  If the air conditioner is knocked over during use, 

turn off the unit and unplug it from the main power 
supply or disconnect the power supply to the unit, 
immediately. Visually inspect the unit to ensure 
there is no damage.

•  If you suspect the unit has been damaged, contact 

a technician or customer service for assistance.

•  In a thunderstorm, the power must be cut off to 

avoid damage to the machine due to lightning.

•  To reduce the risk of fire or electric shock, do not 

use this fan with any solid-state speed control 
device.

•  Do not run cord under carpeting. Do not cover 

cord with throw rugs, runners, or similar coverings. 
Do not route cord under furniture or appliances. 
Arrange cord away from traffic area and where it 
will not be tripped over.

•  If connecting power to fixed wiring, an all-pole 

disconnection device which has at least 3mm 
clearances in all poles, and have a leakage current 
that may exceed 10mA, the residual current 
device(RCD) having a rated residual operating 
current not exceeding 30mA, and disconnection 
must be incorporated in the fixed wiring in 
accordance with the wiring rules.

•  How to fix the appliance to its support, please read 

the “installation instructions” section in this manual.

•  All wiring must be performed strictly in accordance 

with the wiring diagram located inside of the unit.

•  The unit’s circuit board(PCB) is designed with a fuse 

to provide overcurrent protection. The specifications 
of the fuse are printed on the circuit board, such as: 
T 3.15A/250V, etc.

PRIOR TO OPERATION

1.  Contact an installation specialist for installation.

2.  Plug in the power plug properly.

3.  Do not use a damaged or non-standard power cord.

4.  Do not share the same outlet with other appliances.

5.  Do not use an extension cord.

6.  Do not start/stop operation by plugging/unplugging 

the power cord.

USAGE

1.  Exposure to direct airflow for an extended period 

of time could be hazardous to your health. Do not 

expose occupants, pets, or plants to direct airflow 

for extended periods of time.

2.  Due to the possibility of oxygen deficiency, ventilate 

the room when used together with stoves or other 

heating devices.

3.  Do not use this air conditioner for non-specified 

special purposes (e.g. Preserving precision devices, 

food, pets, plants, and art objects). Usage in such a 

manner could harm such property.

CLEANING AND MAINTENANCE

1.  Do not touch the metal parts of the unit when 

removing the filter. Injuries can occur when handling 

sharp metal edges.

2.  Do not use water to clean inside the air conditioner.

Exposure to water can destroy the insulation, 

leading to possible electric shock.

3.  When cleaning and maintenance the unit, first make 

sure that the power and circuit breaker are turned off.

OPERATING TEMPERATURE

1.  Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp 

metal edges.

2.  Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading  

to possible electric shock.

3.  When cleaning and maintenance the unit, first make sure that the power and circuit breaker are turned off.

Cooling operation

Outdoor temp

18–43ºC/64–109ºF (18–52ºC/64–125ºF for special tropical models)

Indoor temp

17–32ºC/62–90ºF

Heating operation

Outdoor temp

-5–24ºC/23–76ºF

Indoor temp

0–27ºC/32–80ºF

 

NOTE: Performance may be reduced outside of these operating temperatures.

AUTO-RESTART (ON SOME MODELS)

1. 

If the unit breaks off unexpectedly due to the power cut, it will restart with the previous function setting 

automatically when the power resumes.

2. 

Wait 3 minutes before resuming operation

3. 

After the unit has stopped, it cannot be restarted operation in the first 3 minutes. This is to protect the unit. 

Operation will automatically start after 3 minutes.

 

WARNING: 

Before installing, remove all packaging from inside the carton, along with any inserts placed into the 

side louvers.

The inserts are found 

in the side louvers

Remove inserts

 

Summary of Contents for EWAC36RC

Page 1: ...UserManual Exactly what you need Model Code s EWAC36RC Online esatto house Product Window Air Conditioner...

Page 2: ...arnings Page 8 Your Air Conditioner Page 9 Operation Instructions Page 11 Installation Instructions Page 18 Troubleshooting Page 19 Specifications Page 20 Warranty Information Page 22 Receipt Page 19...

Page 3: ...r disconnect the power supply to the unit if strange sounds smell or smoke comes from it It may cause fire and electric shock Do not use the socket if it is loose or damaged It may cause fire and elec...

Page 4: ...nection must be incorporated in the fixed wiring in accordance with the wiring rules How to fix the appliance to its support please read the installation instructions section in this manual All wiring...

Page 5: ...E SETTINGS DOWN Press the keypad to decrease the set operating temperature of the unit Each time the keypad is pressed the temperature decreases as follows 1 C Celsius Scale Minimum Setting 16 C FAN P...

Page 6: ...a malfunction of the outdoor condenser temperature sensor Note When one of the above malfunctions occurs turn off the unit and check for any obstructions Restart the unit if the malfunction is still...

Page 7: ...used Please seal it in case leakage is found Operation Instructions Continued Installation Instructions Bottom drain hole Rubber plug Drain outlet Dust pan Rubber plug Screw Back drain hole Bottom dra...

Page 8: ...Remove the front panel and the air filter 1 Hold the slot under the front panel then uplift it outwards and remove the front panel See Fig 1 2 Pinch the handle under the air filter and make the air f...

Page 9: ...r into the frame s slot from upside to underside See Fig 2 2 Hang the front panel on the frame s buckle then press the front panel into the frame s slot until you hear a click See Fig 9 Fig 8 Fig 9 Fi...

Page 10: ...and wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload Air conditioner does not cool as it should Airflow is restricted Make sure there are no curtains blinds...

Page 11: ...laimed is due to faulty or defective parts or workmanship Residentia Group is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abus...

Page 12: ...etails For your records please record details of your purchase below and staple your receipt on the opposite page Your serial number can be found on the rear of your air conditioner STORE DETAILS STOR...

Page 13: ...User Manual 24 This page is intentionally left blank Appliances Exactly what you need A RESIDENTIA GROUP INITIATIVE...

Reviews: