background image

3

These Safety Precautions are for your protection. They summarize pre-

cautionary information from  the references listed in Additional Safety 

Information section. Before performing any installation or operating 

procedures, be sure to read and follow the safety precautions listed 

below as well as all other manuals, material safety data sheets, labels, 

etc. Failure to observe Safety Precautions can result in injury or death.

PROTECT YOURSELF AND OTHERS - Some welding, 

cutting and gouging processes are noisy and require 

ear protection. Hot metal can cause skin burns and 

heat rays may injure eyes. Training in the proper 

use of the processes and equipment is essential to 

prevent accidents. Also:

1.  Always wear safety glasses with side shields in any 

work area, even if welding helmets, face shields, or 

goggles are also required.

2. 

Wear flameproof gauntlet type gloves, heavy long-sleeve shirt, cuff-

less trousers, high-topped shoes, and a welding helmet or cap for hair 

protection, to protect against hot sparks and hot metal. A flameproof 

apron may also be desirable as protection against radiated heat and 

sparks.

3. 

Hot sparks or metal can lodge in rolled up sleeves, trousers cuffs, 

or pockets. Sleeves and collars should be kept buttoned, and open 

pockets eliminated from the front of clothing.

4. 

Protect other personnel from hot sparks with a suitable non-flam-

mable partition or curtains.

5. 

Use goggles over safety glasses when chipping slag or grinding. 

Chipped slag may be hot and can travel considerable distances. 

Bystanders should also wear goggles over safety glasses.

FIRES AND ExPLOSIONS - Heat from a flame can act as an ignition 

source. Hot slag or sparks can also cause fires or ex-

plosions. Therefore:

1.  Remove all combustible materials well away from 

the work area or completely cover the materials with a 

protective non-flammable covering. Combustible mate-

rials include wood, cloth, sawdust, liquid and gas fuels, 

solvents, paints and coatings, paper, etc.

2. 

Hot sparks or hot metal can fall through cracks or crevices in floors or 

wall openings and cause a hidden smoldering fire on the floor below. 

Make certain that such openings are protected from hot sparks and 

metal.

3. 

Do not weld, cut, or perform any other hot work on materials, con-

tainers, or piping until it has been completely cleaned so that no 

substances on the material can produce flammable or toxic vapors. 

Do not do hot work on closed containers. They may explode.

4. 

Have fire extinguishing equipment handy for instant use, such as a 

garden hose, a pail of water or sand, or portable fire extinguisher. Be 

sure you are trained in its use.

5. 

After completing operations, inspect the work area to be sure that 

there are no hot sparks or hot metal which could cause a later fire. 

Use fire watchers when necessary.

6. 

For additional information, refer to NFPA Standard 51B, “Fire Preven-

tion in Use of Cutting and Welding Processes”, which is available from 

the National Fire Protection Association, Batterymarch Park, Quincy, 

MA 02269.

FUMES AND GASES - Fumes and gases, particularly in confined spaces, 

can cause discomfort or injury. Do not breathe fumes or gases from 

welding or cutting, Therefore:

1. 

Always provide adequate ventilation in 

the work area by natural or mechanical ventilation 

means. Do not weld, cut, or gouge on materials such 

as galvanized steel, stainless steel, copper, zinc, lead, 

beryllium, or cadmium unless positive mechanical 

ventilation is provided. Do not breathe fumes and 

gases from these materials.

2. 

If you develop momentary eye, nose, or throat irritation while operat-

ing, this is an indication that ventilation is not adequate. Stop work 

at once and take necessary steps to improve ventilation in the work 

area. Do not continue to operate if physical discomfort persists.

3. 

Refer to ANSI/ASC Standard Z49.1 listed below for specific ventilation 

recommendations.

4.  WARNING: 

This product, when used for welding or cutting, 

produces fumes or gases which contain chemicals 

known to the State of California to cause birth 

defects  and, in some cases, cancer. (California 

Health & Safety Code §25249.5 et seq.)

EQUIPMENT MAINTENANCE - Faulty or improperly maintained equip-

ment, such as torches, hoses and regulators, can result in poor work, 

but even more important, it can cause injury or death through fires. 

Therefore:

1. 

Always have qualified personnel perform the installation, 

troubleshooting, and maintenance work. Do not operate 

or repair any equipment unless you are qualified to do so.

2. 

Keep all oxy-fuel equipment free of grease or oil. Grease, 

oil, and other similar combustible materials, when ignited, can burn 

violently in the presence of oxygen.

3. 

Do not abuse any equipment or accessories. Keep equipment away 

from heat and wet conditions, oil or grease, corrosive atmospheres 

and inclement weather.

4. 

Keep all safety devices in position and in good repair.

5. 

Use equipment for its intended purpose. Do not modify it in any 

manner.

GAS CYLINDER HANDLING - Gas cylinders, if mishandled, can rupture 

or explode violently. Sudden rupture of a cylinder, valve or relief 

device can injure or kill you. Therefore:

1. 

Use the proper gas for the process and use the proper 

pressure reducing regulator designed to operate from the 

compressed gas cylinder. Do not use adaptors to mount 

the regulator on the cylinder. Maintain hoses and fittings 

in good condition. Follow manufacturer’s operating 

instructions for mounting the regulator to the gas cylinder.

2. 

Always secure cylinders in an upright position by chain or strap to 

suitable hand trucks, benches, walls, post, or racks. Never secure 

cylinders to work tables or fixtures where they may become part of 

an electrical circuit.

3. 

When not in use, keep cylinder valves closed. Have the valve protec-

tion cap in place on top of the cylinder if no regulators is installed. 

Secure and move cylinders by using suitable hand trucks. Avoid rough 

handling of cylinders.

4. 

Locate cylinders away from heat, sparks, or flame of a welding, cut-

ting, or gouging operation. Never strike an arc on a cylinder.

5. 

For additional information, refer to CGA Standard P-1, “Precautions for 

Safe Handling of Compressed Gases in Cylinders:, which is available 

from the Compressed Gas Association, 1235 Jefferson Davis Highway, 

Arlington, VA 22202.

ADDITIONAL SAFETY INFORMATION - For more information on safe 

practices for oxy-fuel welding and cutting equipment, ask your 

distributor for a copy of “Precautions and Safe Practices for 

Gas Welding, Cutting, and Heating”, Form 2035. Gas apparatus 

safety guidelines are also available on video cassettes from your 

distributor.

The following publications, which are available from the 

American Welding Society, 550 N.W. LeJuene Road, Miami, 

FL 33126, are recommended to you:

1. 

ANSI/AWS Z49.1 - “Safety in Welding and Cutting”.

2. 

AWS F4.1 - “Recommended Safe Practices for the Prepara-

tion for Welding and Cutting of Containers and Piping That 

Have Held Hazardous Substances”/

3. 

AWS SP - “Safe Practices” - Reprint, Welding Handbook.

Means immediate hazards which, if not avoided, 

will result in immediate, serious personal injury 

or loss of life.

Means potential hazards which could result in 

personal injury or loss of life.

Means hazards which could result in minor per-

sonal injury.

MEANING OF SYMBOLS - As used throughout this 

manual: Means Attention! Be Alert! Your safety is 

involved.

SP-GA 10/98

SAFETY PRECAUTIONS

Summary of Contents for SCT-1500 SERIES

Page 1: ...egulator attach fuel gas hose to the fuel gas station valve or regulator Attachbothhosestotorch Tightenallconnectionsnuts with a wrench 3 Attach nozzle to torch head and tighten connection nut with a wrench 4 Check throttle valve packing nuts for tightness WARNING INSTRUCTIONS for SCT 1500 SERIES CUTTING TORCHES 0558012097 Mar14 Cutting Range using Acetylene 1 8 8 Cutting Range using any fuel gas ...

Page 2: ...used Parts that are broken missing worn distorted or contaminated should be replaced imme diately Should such repair or replacement become necessary the manufacturer recommends that a telephone or written request for service advice be made to the Authorized Distributor from whom it was purchased This equipment or any of its parts should not be altered without the prior written approval of the manu...

Page 3: ... ing this is an indication that ventilation is not adequate Stop work at once and take necessary steps to improve ventilation in the work area Do not continue to operate if physical discomfort persists 3 RefertoANSI ASCStandardZ49 1listedbelowforspecificventilation recommendations 4 WARNING This product when used for welding or cutting producesfumesorgaseswhichcontainchemicals known to the State o...

Page 4: ...4 ...

Page 5: ... have been made make sure all valves on the torch handle are closed Then adjust regulators or open station valves to apply 60 psi oxygen pressure and up to 10 psi fuel gas pressure on the hoses Using Leak Test Solution P N 998771 or any other solu tion suitable for oxygen service check for leaks at the cylinder valves the cylinder to regulator connections the regulator to hose connections and the ...

Page 6: ...15 40 45 39 14Z77 639755 998558 8 200 55 60 5 10 560 590 12 998736 10 250 50 60 840 900 15 20 55 65 31 12 300 60 70 900 970 Use where high preheat intensity is desired Consumption of MAPP or propane is approximately the same as FG 2 Use soft bristled brush 750F99 to clean preheat slots of internal nozzles Heavy duty sleeve 14Z96 available for use in place of 14Z77 sleeve Fuel Gas Two Piece Cutting...

Page 7: ...completely remove cutting valve lever and then unscrew the valve assembly 08M05 You may either replace the entire valve assembly or disassemble the valve assembly to replace valve stem 19216 seat 19215 and O ring 14K11 If the latter unscrew the valve stem from the cap 824 Using the new valve stem seat and O ring reassemble the valve as follows 1 Place the new O ring and retaining washer 10K23 in t...

Page 8: ...00 TOP REAR LEVER PARTS INFORMATION SCT 1500 750 P N 0558011384 SCT 1500 900 P N 0558011385 SPRING 28Z01 PIN 62350048 TRIGGER 17140 NUT 33A56 OXY VALVE 0558010896 CUT VALVE ASSEMBLY 08M05 F G VALVE 0558010895 R H CONNECTOR 0558010834 L H CONNECTOR 0558010835 SCT 1500 BOTTOM FRONT TRIGGER PARTS INFORMATION SCT 1500 750 P N 0558011949 SCT 1500 900 P N 0558011950 ...

Page 9: ...indro abra la válvula del gas combustible en el soplete gire el tornillo de ajuste de presión en el regulador hasta que elmanómetrodesuministrodelreguladorindiquelapresióndeseada vea la tabla en la página 4 Luego cierre inmediatamente la válvula del gas combustible Oxígeno Abralaválvuladeoxígenodecorteaccionandoporcompleto supalanca Gireeltornillodeajustedepresiónhastaqueelmanómetro de suministro ...

Page 10: ...enimiento adecuado Se deberán sustituir inmediatamente las piezas rotas faltantes desgastadas deformadas o contaminadas En caso de que dicha reparación o sustitución sean necesarias el fabricante recomienda que se realice una solicitud de recomendación de servicio telefónica o por escrito al Distribuidor autorizado con quien se compró el equipo No deberá alterarse este equipo o alguna de sus pieza...

Page 11: ...entánea en ojos nariz o garganta mientras está trabajando esto indica que la ventilación no es adecuada Detenga inmediatamente el trabajo y tome los pasos necesarios para mejorar la ventilación en el área de trabajo No continúe operando si las molestias físicas persisten 3 Consulte en la norma ANSI ASC Z49 1 listada a continuación recomen daciones específicas de ventilación 4 ADVERTENCIA Esteprodu...

Page 12: ...12 ...

Page 13: ...de oxígeno de corte y luego reajustar las llamas de precalenta miento a la longitud más corta mediante la apertura de la válvula de oxígeno de precalentamiento gradualmente El procedimiento anterior proporciona por lo general preca lentamiento adecuado o la boquilla en uso Si el deseo de cambiar las llamas de precalentamiento sostenga siempre la válvula de oxígeno de corte abrir mientras reajusta ...

Page 14: ... high preheat intensity is desired Consumption of MAPP or propane is approximately the same as FG 2 Use soft bristled brush 750F99 to clean preheat slots of internal nozzles Heavy duty sleeve 14Z96 available for use in place of 14Z77 sleeve Combustible Gas Boquillas de corte de dos piezas serie 1567 alto precalentamiento Boquillas corte acetileno 1502 Series medio precalentamiento Utilice un cepil...

Page 15: ...nvíe el soplete a una estación de reparación para el reasentamiento del cuerpo Después de instalar un nuevo conjunto de la válvula reguladora ajuste la tuerca de empaque hasta que la válvula se pueda girar solamente con mucha dificultad y aparte la unidad durante tres o cuatro horas al menos para establecer el empaque Luego afloje la tuerca de empaque hasta que la válvula gire fácilmente Válvula d...

Page 16: ...R SCT 1500 INFOR MACIÓN SOBRE LAS PIEZAS SCT 1500 750 P N 0558011384 SCT 1500 900 P N 0558011385 RESORTE 28Z01 PIN 62350048 GATILLO 17140 TUERCA 33A56 VÁLVULA DE OXÍGENO 0558010896 MONTAJE DE LA VÁLVULA DE CORTE 08M05 VÁLVULA F G 0558010895 CONECTOR R H 0558010834 CONECTOR L H 0558010835 SCT 1500 DELANTERO INFERIOR DEL GATILLO INFORMACIÓN SOBRE LAS PIEZAS SCT 1500 750 P N 0558011949 SCT 1500 900 P...

Page 17: ...ouvrir légèrement la vanne de station Si le gaz combustible est fourni par une station ou un régulateur ouvrir la vanne du gaz combustible sur le chalumeau tourner la vis de réglage depressionsurlerégulateurjusqu àcequelemanomètredu régulateurindiquelapressionsouhaitée voirlediagramme de la page 4 Fermer immédiatement la vanne du gaz combustible Oxygène Ouvrirlavanned oxygènedecoupeenappuyant sur ...

Page 18: ...nt qui fonctionne mal ou mal entretenu ne doit jamais être utilisé Remplacez immédiatement les pièces brisées manquantes usées déformées ou contaminées S il devient nécessaire de réparer ou de remplacer la machine le fabricant recommande de téléphoner ou d écrire au distributeur autorisé où vous avez acheté l appareil pour demander des renseignements concernant la réparation Il est interdit de mod...

Page 19: ...s yeux du nez ou de la gorge durant l exploitation cela indique que la ventilation est inadéquate Arrêtez immédiatement le travail et prenez les dispositions nécessaires pour améliorer la ventilation de la zone de travail Si les désagréments physiques persistent ne reprenez pas le travail 3 Reportez vous à la norme ANSI ASC Z49 1 exposée plus bas pour des recommandations spécifiques à la ventilati...

Page 20: ...20 ...

Page 21: ...ssurer que toutes les vannes sur la poignée du chalumeau sont fermées Régler ensuite les régulateurs ou ouvrir les vannes de la station pour appliquer une pression d oxygène de 4 bar 60 psi et jusqu à 0 7 bar 10 psi de pression de gaz sur les tuyaux Avec le Leak Test Solution réf 998771 ou toute autre solution pour oxygène inspecter pour détecter les fuites au niveau des vannesdelabouteille descon...

Page 22: ... 300 60 70 900 970 Use where high preheat intensity is desired Consumption of MAPP or propane is approximately the same as FG 2 Use soft bristled brush 750F99 to clean preheat slots of internal nozzles Heavy duty sleeve 14Z96 available for use in place of 14Z77 sleeve Gaz combustible Buses de coupe en deux pièces 1567 Series haute préchauffage Buses de coupe d acétylène 1502 Series par préchauffag...

Page 23: ...plètement envoyer le chalumeau à un centre de réparation Après avoir installé un nouveau délimiteur de débit resserrer l écrou de la garniture jusqu à ce que la vanne puisse être tournée uniquement avec difficulté et mettre l unité de côté pendant trois à quatre heures au moins pour permettre à la garniture de s adapter Desserre ensuite l écrou de la garniture jusqu à ce que la vanne puisse tourne...

Page 24: ...ÉRIEUR SCT 1500 INFORMATIONS SUR LES PIÈCES SCT 1500 750 Réf 0558011384 SCT 1500 900 Réf 0558011385 RESSORT 28Z01 GOUPILLE 62350048 TRIGGER 17140 ÉCROU 33A56 VANNE OXY 0558010896 VANNE DE COUPE 08M05 VANNE GAZ COMB 0558010895 CONNECTEUR DROIT 0558010834 CONNECTEUR GAUCHE 0558010835 SCT 1500 BAS AVANT TRIGGER INFORMATIONS SUR LES PIÈCES SCT 1500 750 Réf 0558011949 SCT 1500 900 Réf 0558011950 ...

Page 25: ...25 NOTES ...

Page 26: ...26 NOTES ...

Page 27: ...27 NOTES ...

Page 28: ...x 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires Tel 54 11 4 753 4039 Fax 54 11 4 753 6313 BRAZIL ESAB S A Contagem MG Tel 55 31 2191 4333 Fax 55 31 2191 4440 CANADA ESAB Group Canada Inc Missisauga Ontario Tel 1 905 670 02 20 Fax 1 905 670 48 79 MEXICO ESAB Mexico S A Monterrey Tel 52 8 350 5959 Fax 52 8 350...

Reviews: