-- 20 --
bm38d1ea
OrigoFeed 30--4
1
Knob for setting wire feed
speed
6
Connection for welding gun
2
Switch for activation of 2/4 stroke, spot
welding, cold wire feed or gas purging
7
Connection for welding current from power
source, (OKC)
3
Knob for setting spot welding time
8
Connection for shielding gas
4
Knob for setting burnback time
9
Connection for control cable from power
source
5
Switch for creep start OFF / ON
6.2
Explanation of function
Wire feed speed
This sets the required feed speed of the filler wire in m/minute.
2 stroke
With 2--stroke, the gas flow starts followed by the wire feed when the trigger switch is
pressed in. The welding process is concluded when the trigger switch is released,
the wire feed stops and the gas stops flowing.
4 stroke
With 4 stroke, the gas flow starts when the trigger switch is pressed in and the wire
feed starts when it is released. The welding process continues until the switch is
pressed in again, the wire feed stops and when the switch is released the gas stops
flowing.
Spot welding
Spot welding is used when you want to weld on short, repeated occasions with a
pre--set time.
When the trigger switch is pressed in, the gas flow starts for a period of time
governed by the printed circuit board. After this the welding process starts for the set
time. When the welding process is complete, the gas flow stops.
GB