-- 19 --
bm38d1ea
WARNING!
Rotating parts can cause injury, take great care.
WARNING!
There is a risk of tipping if the wire feed unit is fitted with a counterbalance arm. Secure the
equipment, especially if used on an uneven or sloping surface.
When moving the equipment use intended handle.
NOTE!
Never pull on the gun.
6.1
Connections and control devices
Connecting control cable
When connecting the control cable, it is
important to secure the cable with the
load--removing grommet.
Ensure that the cover is properly screwed
into place.
OrigoFeed 30--2
1
Knob for setting wire feed speed
4
Connection for welding gun
2
Knob for setting burnback time
5
Connection for welding current from power
source, (OKC)
3
Switch for 2--stroke / 4--stroke
6
Connection for shielding gas
7
Connection for control cable from power
source
GB