4.2 OPERATING PROCEDURES
Comply with all ventilation, fire and other safety re-
quirements for arc welding as established in the
SAFETY Section at the front of this manual.
4.2.1 MIG WELDING SET-UP
When the PROCESS switch is placed in the MIG position
the Multimaster 160 is set to turn ”ON” when the Mig Gun
trigger is depressed.
Step 1. Choose the weld parameters based of the wire
alloy, diameter, material thickness and shielding
gas from Table 3 - MIG PARAMETERS CHART.
Set the polarity as shown in Filgure 10 for the
process being used.
Step 2. Place the WELD PROCESS (1) switch in the MIG
(FAR RIGHT) position.
Step 3. Turn the Wire Speed Knob (2) to the desired
speed.
Step 4. Turn the VOLTAGE (3) knob to the desired arc
voltage.
Step 5. Pull the gun trigger and start welding. Trim the
wire speed and volts as needed for the desired
arc characteristics.
Figure 10 - MIG Polarity Connection
SECTION 4
OPERATION
Figure 11 - Front Control Panel -
MIG (GMAW) Process Setup
Table 3 - MIG PARAMETERS CHART
Option: If using one, set the shielding gas flow rate to 35
cfh by pulling the gun trigger and turning the ad-
justment knob on the R33-FM 580 Flowmeter.
MIG - DCEP (Electrode Positive)
Work Cable
and Clamp
Polarity
Changeover
Connector
MIG Gun
Connector
1
2
3
Summary of Contents for MultiMaster 160
Page 1: ...MultiMaster 160 Mig Tig Stick Welding Package F15 678 D 07 2005 Instruction Manual...
Page 4: ...4 Table of Contents...
Page 24: ...24 12 11 10 14 6 5 16 3 7 4 15 8 13 18 17 19 20 Feed Motor SECTION 6 REPLACEMENT PARTS...
Page 26: ...26 Multimaster 160 Bottom Plate 61 62 63 68 64 67 66 65 SECTION 6 REPLACEMENT PARTS...
Page 28: ...28 Notes...
Page 29: ...29 Notes...
Page 30: ...30 Notes...