3 TECHNICAL DATA
0447 209 001
- 9 -
© ESAB AB 2022
3
TECHNICAL DATA
Fabricator ET 410iP
Mains voltage
400 V ±15%,
3~ 50/60 Hz
Primary current I
max
MMA
31 A
TIG
25 A
Idle state power
(fan stop running)
U
in
400 V
40 W (VRD OFF)
15 W (VRD ON)
Setting range
MMA
30 A/21.2 V - 410 A/36.4 V
TIG
5 A/10.2 V - 410 A/26.4 V
Permissible load at MMA
60 % duty cycle
410 A/36.4 V
100% duty cycle
310 A/32.4 V
Permissible load at TIG
60 % duty cycle
410 A/26.4 V
100% duty cycle
310 A/22.4 V
Apparent power I
2
at maximum current
21 kVA
Active power I
2
at maximum current
17 kW
Power factor
at maximum current
MMA
0.82
TIG
0.79
Efficiency
at maximum current
MMA
88 %
TIG
86 %
Open-circuit voltage U
0
max
VRD deactivated
76 V
VRD activated (standard setting at delivery)
13.5 V
Operating temperature
-10 to +40 °C (+14 to +104 °F)
Transportation temperature
-20 to +55 °C (-4 to +131 °F)
Constant sound pressure when idling
<70 db (A)
Dimensions l × w × h
525 × 280 × 475 mm
Weight
38.5 kg (84.88 lbs)
Insulation class
F
Enclosure class
IP 23S
Application class