6 CONTROL PANEL
0447 209 001
- 21 -
© ESAB AB 2022
6.2
TIG settings
Indicator
Function
Setting range
Setting step
Default value
Available mode
HF on
HF on or off
on/off
on
DC TIG/Pulse TIG
2T/4T/4TS/SPOT
Pre flow
Gas preflow
time (s)
0.1-2.0
0.1
0.5
DC TIG/Pulse TIG
2T/4T/4TS/SPOT
Start pulse
Start pulse
current (A)
0-100
1
30
DC TIG/Pulse TIG
2T/4T/4TS/SPOT
HFON
Initial current Initial current 5-set current
1
15
DC TIG/Pulse TIG
4T/4TS
Slope up
Slope up time
(s)
0.0-5.0
0.1
1.0
DC TIG/Pulse TIG
4T/4TS
Set current
Set current
(A)
5-410
1
100
DC TIG/Pulse TIG
2T/4T/4TS/SPOT
Background
current
Background
current (A)
5-set current
1
50
Pulse TIG
4T/4TS
Slope down
Slope down
(s)
0.0-5.0
0.1
1.0
DC TIG/Pulse TIG
2T/4T/4TS
Final current
Final current
(A)
5-set current
1
20
DC TIG/Pulse TIG
4T/4TS
Post flow
Post flow (s)
0.5-20.0
0.1
3.0
DC TIG/Pulse TIG
2T/4T/4TS/SPOT
% Pulse
Duty cycle of
pulse (%)
10-90
1
50
Pulse TIG
2T/4T/4TS/SPOT
Pulse Hz
Frequency of
pulse (Hz)
0.5-250
0.1(0.5-20.0);
1(20-250)
1.0
Pulse TIG
2T/4T/4TS/SPOT
Spot
Spot times (s) 0.1-20
0.1
2.0
DC TIG/Pulse TIG
SPOT
6.2.1
Measured values
Measured current
Measured value in the display for welding current A is arithmetic average value.
Measured voltage
Measured value in the display for arc voltage V is arithmetic average value.