TROUBLESHOOTING
6-13
6.03 LED Diagnostics
The unit has several LEDs that can assist in diagnosing problems.
POWER PCB2 / (15AP1)
D42
+24V_SEC OK
+24VDC Supply on this pcb is present
D53
+18V_PRI OK
+18VDC Supply on this pcb is present
CONTROL PCB3 / (20AP1)
D33
PWM IGBT
Gate signals are enabled (Brightness depends on PWM demand)
D35
PS_OK
+15VDC & -15VDC Supply on this PCB is present.
D36
3,3V_1 OK
+3.3VDC Supply on this PCB is present
D40
+24V_1 LOW
Problem: +24VDC Supply on this PCB is low
D43
BUS V ERROR
Problem: Buss Voltage from PCB3 is less than 350VDC
D44
UI COM
Communication from PCB1 is established
D45
uP OK
If flashing, u processor. On this pcb is active
D85
10.3V_VB OK
+10.3 VDC Supply on this PCB is present
D86
+5V_1 OK
+5VDC Supply on this PCB is present
D87
MIG SOL ON
Signal is active to turn on MIG gas solinoid
D88
TRIGGER ON
Remote trigger is closed
D89
TIG SOL ON
Signal is active to turn on TIG Solenoid (IF INSTALLED)
D90
FAN ON
Fan control signal is on, fans should be running
6.04 Initial Power Up Test
Using Generators or Extension cords
If a problem is encountered while running on a generator or while using an extension cord, note the problem
and then plug the unit directly into a Mains Power Outlet. If the problem is no longer found, there is a problem
with the power from the generator or the extension cable is too long or wire gauge is too small to adequately
power the unit. Measure the incoming voltage at the units Mains Power Cable/Plug both before and while the
unit is under load to verify voltage does not drop under load conditions, especially when connecting to 120VAC.
Interconnections
When performing tests to determine failed component, check for open wires or poor connection between
components, pcbs, connectors, etc.
Wire Feedability Problems
Many welding problems, gun and consumable issues can be caused by improper wire feed set up, incorrect
or worn parts. Pay close attention to the following items:
Wire spool – Wire feeds smoothly off spool – no friction or wire cross over
Wire Spool Hub Brake Tension
Drive Roll - Size, style and condition
Wire Guides – Size and condition
Wire Tension Adjustment
Wire Liner (Conduit) - Size and condition
Contact Tip – Size and condition
Wire type
Gun Polarity
Summary of Contents for EMP 215ic
Page 16: ...ESAB EMS215C EMP215C 1 8 SAFETY INSTRUCTIONS Manual 0463 413 001 This Page Intentionally Blank...
Page 31: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 OPERATION 3 9...
Page 43: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 POWER SUPPLY INTRODUCTION 5 5 A 12892_AA...
Page 45: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 POWER SUPPLY INTRODUCTION 5 7 A 13146_AA...
Page 78: ...ESAB EMS215IC EMP215IC 6 32 TROUBLESHOOTING Manual 0463 413 001 This Page Intentionally Blank...
Page 88: ...ESAB EMS215IC EMP215IC 8 8 REPLACEMENT PARTS Manual 0463 413 001 This Page Intentionally Blank...
Page 95: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 APPENDIX A 3 A 12892_AA...
Page 97: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 APPENDIX A 5 A 13146_AA...
Page 99: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 APPENDIX A 7 This Page Intentionally Blank...
Page 101: ...This Page Intentionally Blank...