ESAB EMS215IC/EMP215IC
6-12
TROUBLESHOOTING
Manual 0463 413 001
An additional Pre Power-up check for the Output Diodes D66 – D69 should be performed. Using a meter set
in the DIODE TEST setting do the following:
1 With positive meter lead on – OUTPUT WELD terminal and with negative meter lead on + WELD OUT-
PUT terminal, check for forward biased diode drop reading.
2 With positive meter lead on + OUTPUT WELD terminal and with negative meter lead on - WELD OUTPUT
terminal, check for reverse biased diode drop reading.
If an open or short is found, Replace OUTPUT DIODE PCB4.
The following image shows the previous steps listed. In the oval you will see the step number and below that
the meter reading you should see.
1
0.3 - 0.7 VDC
2
Open /Infinity
+
-
-
+
This concludes the Pre Power-up Checks.
Summary of Contents for EMP 215ic
Page 16: ...ESAB EMS215C EMP215C 1 8 SAFETY INSTRUCTIONS Manual 0463 413 001 This Page Intentionally Blank...
Page 31: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 OPERATION 3 9...
Page 43: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 POWER SUPPLY INTRODUCTION 5 5 A 12892_AA...
Page 45: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 POWER SUPPLY INTRODUCTION 5 7 A 13146_AA...
Page 78: ...ESAB EMS215IC EMP215IC 6 32 TROUBLESHOOTING Manual 0463 413 001 This Page Intentionally Blank...
Page 88: ...ESAB EMS215IC EMP215IC 8 8 REPLACEMENT PARTS Manual 0463 413 001 This Page Intentionally Blank...
Page 95: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 APPENDIX A 3 A 12892_AA...
Page 97: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 APPENDIX A 5 A 13146_AA...
Page 99: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 APPENDIX A 7 This Page Intentionally Blank...
Page 101: ...This Page Intentionally Blank...