CUTMASTER A60
SERVICE
0-5428
5-8
!
WARNING
Always turn OFF the air supply and
bleed the system before disassembling
the Filter Assembly as injury could
result.
3. Loosen the two bolts on the top of the Filter As-
sembly enough to allow the Filter Elements to
move freely.
4. Note the location and orientation of the old Filter
Elements.
5. Slide out the old Filter Elements.
First & Second
Stage
Cartridges
(as marked)
Art # A-02942
Optional Two-Stage Filter Replacement
6. Slide the replacement Filter Elements into the
Filter Assembly, with the same orientation as
noted in Step 4 above.
7. Hand tighten the two bolts evenly, then torque
each bolt to 20 - 30 in-lbs (2.3 - 3.4 Nm). Im
-
proper torque may damage the gasket.
8. Slowly apply air pressure to the assembly, check-
ing for leaks.
NOTE!
A small amount of air leakage from the
bottom fitting is normal.
This completes the parts replacement procedures.
Summary of Contents for CUTMASTER A40
Page 5: ......
Page 8: ...This Page Intentionally Blank...
Page 18: ...CUTMASTER A60 INTRODUCTION 0 5428 2T 4 This Page Intentionally Blank...
Page 24: ...CUTMASTER A60 INSTALLATION 0 5428 3 6 This Page Intentionally Blank...
Page 32: ...CUTMASTER A60 OPERATION 0 5428 4 4 This Page Intentionally Blank...
Page 58: ...CUTMASTER A60 OPERATION 0 5428 4T 26 This page intentionally blank...
Page 59: ...CUTMASTER A60 0 5428 OPERATION 4T 27 This page intentionally blank...
Page 80: ...CUTMASTER A60 OPERATION 0 5428 4T 48 This Page Intentionally Blank...
Page 98: ...CUTMASTER A60 PARTS LIST 0 5428 6 8 This Page Intentionally Blank...
Page 111: ...This page intentionally blank...