CUTMASTER A60
INSTALLATION
0-5428
3-2
3.05 Primary Input Power Connections
!
CAUTION
Check your power source for correct
voltage before plugging in or connecting
the unit. Check the Voltage Selector at
the rear of the unit for correct setting be-
fore plugging in or connecting the unit.
The primary power source, fuse, and
any extension cords used must conform
to local electrical code and the recom-
mended circuit protection and wiring
requirements as specified in Section 2.
Most units are shipped from the factory with a 230 Volt
input power cable wired to the input contactor in the
single - phase configuration. The following illustrations
and directions are for changing that configuration to a
different voltage and or to three - phase operation or back
again if a change had already been made.
A. Cover Removal
1. Remove the upper and lower screws which
secure the cover to the main assembly. Do not
loosen the lower screws inside the cut out slots
in the bottom of the cover.
NOTE!
The upper screws and lower screws
are not the same. Do not mix them.
The upper screws are for threading into
the plastic of the front and rear panels.
DO NOT use the finer threaded lower
screws for this.
Upper
Screws
Lower
Screws
Lower
Screws
Art # A-08317
Slots
2. Carefully pull the Cover up and away from the
unit.
B. Cover Installation
1. Reverse previous procedures for cover installa-
tion.
NOTE!
When installing the upper screws, at-
tempt to reuse the original threads. The
easiest way to do this is by turning the
screw counter-clockwise until you feel
the threads line up, then begin to turn
the screw clockwise to tighten.
Do not
over tighten.
C. Input Power Selection
Set the Input Voltage Selection Switch at the rear of the
unit based on the primary input voltage it is connected
to. Low is 208/230 VAC and high is 460 VAC.
S
LO
HI
Art # A-08316
D. Quick Guide to Phase Wiring
Art # A-07984_AB
Single-Phase (1ø) and Jumper Settings
L1
L2
L3
L4
Jumper L1 -L4
Jumper
L2-L3
L1
L2
L3
GND
L4
Single Phase Input Power Wiring
Art # A-07983_AB
Three-Phase (3ø) and Jumper Settings
L1
L2
L3
L4
Jumper L1 -L4
L1
L2
L3
GND
L4
Store copper jumper in spare parts box
Three Phase Input Power Wiring
Summary of Contents for CUTMASTER A40
Page 5: ......
Page 8: ...This Page Intentionally Blank...
Page 18: ...CUTMASTER A60 INTRODUCTION 0 5428 2T 4 This Page Intentionally Blank...
Page 24: ...CUTMASTER A60 INSTALLATION 0 5428 3 6 This Page Intentionally Blank...
Page 32: ...CUTMASTER A60 OPERATION 0 5428 4 4 This Page Intentionally Blank...
Page 58: ...CUTMASTER A60 OPERATION 0 5428 4T 26 This page intentionally blank...
Page 59: ...CUTMASTER A60 0 5428 OPERATION 4T 27 This page intentionally blank...
Page 80: ...CUTMASTER A60 OPERATION 0 5428 4T 48 This Page Intentionally Blank...
Page 98: ...CUTMASTER A60 PARTS LIST 0 5428 6 8 This Page Intentionally Blank...
Page 111: ...This page intentionally blank...