SERVICE INSTRUCTIONS
0740 800 186
- 45 -
© ESAB AB 2016
Special equipment
To measure the gate pulses, you need a gate pulse load. This is included in soft-starting tool
SST 3, which is described earlier in this chapter.
Instructions
1. Disconnect the power source from the mains.
2. Disconnect connector 20XS5 from terminal G on control board 20AP1.
3. Connect the gate pulse test cable of the SST 3 to terminal G on control board 20AP1.
Measuring connection for the gate pulses
4. Switch on the power source.
5. Connect an oscilloscope to the SST 3, with the probe to terminal G2 and the screen to
terminal G1 of SST 3.
6. Set the machine to MMA welding mode.
7. Measure the pulse frequency. It must be 65 kHz +/- 1kHz.
8. Measure the duration of the negative pulse. It must be 41 - 43 % of the cycle time,
measured at a voltage level of -10 V.
9. The waveform of the pulses must be as shown below.
Gate pulses from circuit board 20AP1