![ESAB Caddy Tig 1500i TA34 Service Manual Download Page 34](http://html1.mh-extra.com/html/esab/caddy-tig-1500i-ta34/caddy-tig-1500i-ta34_service-manual_2424956034.webp)
DESCRIPTION OF OPERATION
0740 800 186
- 34 -
© ESAB AB 2016
1. The welder releases the trigger switch.
2. Welding stops.
3. The water pump continues to run for a further 6.5 minutes.
If welding is restarted while the pump is still running, the pump will continue to run as
required, i.e. the 6.5 minute shutdown countdown is interrupted.
Flow guard can not be installed in the CoolMini. The flow guard input is jumpered with wire
541 in the cooler, the behaviour is as if the cooling water is always flowing.
Microswitch 5S2 in the water lock connector closes when a cooling water hose is connected
to the blue water connector on the front of the cooling unit. The pump stops if the switch
opens.
20AP1 Component positions
Version 2 of the control board
There are two hardware versions of the control board. See section "20AP1:7 Arc voltage
feedback" of this chapter for description of the differnce in function between the two versions.
The print number of the circuit board is used to identify the hardware version of the board.
The print number is to the right in the component positions diagram above. (The print number
is NOT the same as the ordering number of the board.)
Summary of Contents for Caddy Tig 1500i TA34
Page 10: ...WIRING DIAGRAM 0740 800 186 10 ESAB AB 2016 Tig 1500i with control panel TA34 ...
Page 11: ...WIRING DIAGRAM 0740 800 186 11 ESAB AB 2016 ...
Page 12: ...WIRING DIAGRAM 0740 800 186 12 ESAB AB 2016 Tig 2200i with control panels TA33 and TA34 ...
Page 13: ...WIRING DIAGRAM 0740 800 186 13 ESAB AB 2016 ...
Page 20: ...DESCRIPTION OF OPERATION 0740 800 186 20 ESAB AB 2016 ...