SERVICE INSTRUCTIONS
0740 800 186
- 42 -
© ESAB AB 2016
Checking the semiconductor module of 15AP1
Measuring points for the semiconductor module, PM1
Disconnect the power source from the mains and follow the instructions below.
Measurements 2 - 6: Use a multimeter in diode test position to measure the diodes.
Measure with the positive and negative of the multimeter connected as shown in the picture
above. The main transformer must be connected to terminals T1 and T2.
1. Resistor R31 (and thyristor TY1 in parallel): measure the resistance of R31. It must be 12
ohm (on some boards the resistance of R31 is 6.8 or 10 ohm, which are also approved
values).
2. PM1, diode P1D: measure between resistor R31 and terminal N1.
PM1, diode P2D: measure between resistor R31 and terminal N2.
The forward voltage drop must be 0.4 to 0.6 V.
3. PM1, diode N1D: measure between the negative of capacitor 15C1 and terminal N1.
PM1, diode N2D: measure between the negative of capacitor 15C1 and terminal N2.
The forward voltage drop must be 0.4 to 0.6 V.
4. PM1, diode D2: measure between the negative of capacitor 15C1 and terminal T2. The
forward voltage drop must be 0.3 to 0.5 V.
Summary of Contents for Caddy Tig 1500i TA34
Page 10: ...WIRING DIAGRAM 0740 800 186 10 ESAB AB 2016 Tig 1500i with control panel TA34 ...
Page 11: ...WIRING DIAGRAM 0740 800 186 11 ESAB AB 2016 ...
Page 12: ...WIRING DIAGRAM 0740 800 186 12 ESAB AB 2016 Tig 2200i with control panels TA33 and TA34 ...
Page 13: ...WIRING DIAGRAM 0740 800 186 13 ESAB AB 2016 ...
Page 20: ...DESCRIPTION OF OPERATION 0740 800 186 20 ESAB AB 2016 ...