- 80 -
MAINTENANCE
The unit is maintenance-free. The following points should be checked regularly:
•
Mains plug and cable as well as the welding torch and earth connection from time to time for
damage.
•
After every package of electrodes or after 30-40 hours of TIG welding operation, blow out
the unit with dry compressed air at low pressure. For this purpose, switch off the unit and
pull the mains plug. Blow the compressed air from the front through the ventilating grill to the
rear. Leave the housing closed. Never blow the compressed air through the grill on the rear
of the unit. A ventilating fan is located there that would be brought to such a high rotating
speed by the compressed air that the bearing could be damaged.
ACCESSORIES
Remote control unit:
The hand remote regulator PHA1 (Order-No. 0367 657-881) and the foot pedal remote regulator
FS00
3
(Order-No. 0
700 155 880
) can be connected.
TIG torch and electrode holder:
Information concerning other TlG torches, electrode holder and remote control units as well as
additional accessories are contained in separate brochures.
NOTES:
Summary of Contents for Aristotig 405 AC/DC
Page 1: ...0458 165 002 9910 DTG 405 Aristotig 405 AC DC Welding rectifier Service manual...
Page 9: ...9 NOTES...
Page 10: ...10 CONNECTION DIAGRAM DTG 405...
Page 11: ...11...
Page 15: ...15 NOTES...
Page 16: ...16 BLOCK DIAGRAM DTG 405 405a pcx...
Page 17: ...17 Warning Some parts of this circuit are connected to mains voltage potential 405b pcx...
Page 27: ...27 A2 COMPONENT POSITIONS a2 1b pcx a2 2b pcx...
Page 40: ...40 A9 A13 COMPONENT POSITIONS A10 A14 COMPONENT POSITIONS...
Page 62: ...62 8 WAVEFORM AC2 SMOOTH WAVE ac2 pcx...
Page 81: ...81 NOTES...
Page 91: ...page...