- 77 -
TIG four-stroke welding process
1.
The gas pre-flow time has an internal fixed default value.
2.
Set ignition current I1 using the potentiometer (25).
3.
Set Up-Slope using the potentiometer (9), at maximum (I2=400A) a ramp time of 10s is
obtained. The ramp time is dependant on the set welding current I2.
4.
Set welding current I2 using the potentiometer (27).
5.
Set Down-Slope using the potentiometer (14), at maximum (I2=400A) a ramp time of 10s is
obtained. The ramp time is dependant on the set welding current I2.
6.
Set final current I3 using the potentiometer (30)
7.
Set gas post-flow time using the potentiometer (18) 0.2–30 s.
7.1.3
TIG TWO-STROKE WELDING
Step 1: By pressing the torch switch the gas flows for the preset time and the ARC ignites at a
current level set by potentiometer I1 (25).
After a fixed time the current rises at a rate set by the up-slope control (9) to the welding
current value set by the potentiometer I2 (27).
Step 2: By releasing the torch button, the current slopes down to the set final current in the time
set using the potentiometer Down-Slope. Afterwards, the arc extinguishes and the gas
post-flow time runs off.
2
4
5
6
7
3
1
Summary of Contents for Aristotig 405 AC/DC
Page 1: ...0458 165 002 9910 DTG 405 Aristotig 405 AC DC Welding rectifier Service manual...
Page 9: ...9 NOTES...
Page 10: ...10 CONNECTION DIAGRAM DTG 405...
Page 11: ...11...
Page 15: ...15 NOTES...
Page 16: ...16 BLOCK DIAGRAM DTG 405 405a pcx...
Page 17: ...17 Warning Some parts of this circuit are connected to mains voltage potential 405b pcx...
Page 27: ...27 A2 COMPONENT POSITIONS a2 1b pcx a2 2b pcx...
Page 40: ...40 A9 A13 COMPONENT POSITIONS A10 A14 COMPONENT POSITIONS...
Page 62: ...62 8 WAVEFORM AC2 SMOOTH WAVE ac2 pcx...
Page 81: ...81 NOTES...
Page 91: ...page...