OVERHEATING PROTECTION
•
An integrated thermal cut-out in the welding device protects the equipment from
overheating.
•
The welding process is interrupted and the fault display (16) indicates error "4" .
•
The equipment must be left in that condition to cool with the main switch left in the on posi-
tion and the cooling fans running.
CAUTION! When the error indicator "4" disappears, the position "Electrode" has to be set to the
open circuit voltage on the electrode; on position "TIG" the welding device can now be started with
the torch button. After cooling, the device is reconnected automatically.
Care must be taken to ensure that the electrode does not touch the welding table, the workpiece
or any other electrical conducting object during the cooling phase of the power source in order to
prevent unintentional arc ignition when switching it on again.
An unintentionally ignited arc may damage the electrode holder, the workpiece or the equipment.
5
CONTROL PANEL
1 Potentiometer,
spot time
This potentiometer allows the duration of the spot time to be set
to values in the range from 0.1 to 10 s.
2 Operation
mode selector
•
Electrode welding with rod electrodes.
•
TIG spot welding
•
TIG four-step welding
•
TIG two-step welding
3
LED,
external current
selection
LED illuminates, when the foot operated or hand operated re-
mote controls are connected and are controlling the welding cur-
rent.
4 LED,
mains
The green LED illuminates when the device is connected to the
mains and the mains switch is activated.
5 LED,
foot operated
remote control
LED illuminates, when a foot operated remote control is connect-
ed, i.e. that the set point is fixed externally and the arc can be
started using the torch button as well as via the pedal.
Summary of Contents for Aristotig 405 AC/DC
Page 1: ...0458 165 002 9910 DTG 405 Aristotig 405 AC DC Welding rectifier Service manual...
Page 9: ...9 NOTES...
Page 10: ...10 CONNECTION DIAGRAM DTG 405...
Page 11: ...11...
Page 15: ...15 NOTES...
Page 16: ...16 BLOCK DIAGRAM DTG 405 405a pcx...
Page 17: ...17 Warning Some parts of this circuit are connected to mains voltage potential 405b pcx...
Page 27: ...27 A2 COMPONENT POSITIONS a2 1b pcx a2 2b pcx...
Page 40: ...40 A9 A13 COMPONENT POSITIONS A10 A14 COMPONENT POSITIONS...
Page 62: ...62 8 WAVEFORM AC2 SMOOTH WAVE ac2 pcx...
Page 81: ...81 NOTES...
Page 91: ...page...