- 29 -
SIGNAL DESCRIPTION X4
Control bus to inverter X1 from A8, to X4 from A2-1
Pin
No.
Signal
Source
Level
Description
1
A8
+15 V
Error: thermal overload of power stage, low active
2
A8
+15 V
Error: mains overvoltage, low active
3
A8
+15 V
Error: mains undervoltage, low active
4
A8
+15 V
Error: primary overcurrent, shut down of power stage, low active
5
A8
+15 V
Error: error interrupt (group fault), low active
6
A8
+15 V
I>0, high active
7
GND
GND
Logic Ground
8
A8
0-10 V
Current value (Strom Istwert)
9
A2
0-10 V
Current set value (Strom Solllwert)
10
A2
+15 V
Start / Stop of power stage
11
A2
0-10 V
AC welding current frequency
12
A2
0-10 V
AC welding current balance
13
A2
+15 V
DC mode / AC mode (high active for AC)
14
A2
+15 V
Positive polarity for DC in MMA mode, high active
15
A2
+15 V
Positive polarity start-up time for AC mode, low active
16
Not relevant for the DTG 405
17
Not relevant for the DTG 405
18
Not relevant for the DTG 405
19
A2
+5 V
address Bit 1 for AC current wave shape
20
A2
+5 V
address Bit 2 for AC current wave shape
21
A2
+5 V
address Bit 3 for AC current wave shape
22
Not relevant for the DTG 405
23
Not relevant for the DTG 405
24
Not relevant for the DTG 405
25
A2
+15 V
MMA mode low active / TIG mode high active
26
A8
+15 V
3-phase mains supply identification, high active
Summary of Contents for Aristotig 405 AC/DC
Page 1: ...0458 165 002 9910 DTG 405 Aristotig 405 AC DC Welding rectifier Service manual...
Page 9: ...9 NOTES...
Page 10: ...10 CONNECTION DIAGRAM DTG 405...
Page 11: ...11...
Page 15: ...15 NOTES...
Page 16: ...16 BLOCK DIAGRAM DTG 405 405a pcx...
Page 17: ...17 Warning Some parts of this circuit are connected to mains voltage potential 405b pcx...
Page 27: ...27 A2 COMPONENT POSITIONS a2 1b pcx a2 2b pcx...
Page 40: ...40 A9 A13 COMPONENT POSITIONS A10 A14 COMPONENT POSITIONS...
Page 62: ...62 8 WAVEFORM AC2 SMOOTH WAVE ac2 pcx...
Page 81: ...81 NOTES...
Page 91: ...page...