S0740 800 196/E101019/P76
- 61 -
ca41f3term
CONNECTION OF TERMINATING RESISTORS
Abbrevations used in this chapter
MMC
=
M
an
M
achine
C
ommunication
The MMC unit is a control panel with display, in some cases it also incorporates a welding
data board, see WDU below.
WDU
=
W
elding
D
ata
U
nit.
The welding data unit handles the overall control of the system. The WDU is a part of the
system software.
In MIG applications it is run by a separate processor on a separate board, named the
welding data board. The welding data board is enclosed in the MMC unit.
In MMA and TIG applications the WDU uses a part of the processor of the power source
control board.
Symbol explanation
Fixed terminating resistor on circuit board =
Terminating resistor on circuit board, disconnected =
Terminating resistor on circuit board, connected by a jumper =
The welding data unit of MMC unit A24 has no terminating resistor.
Mig 3001i
Power source without MMC
Power source
Wire feed unit
MMC & WDU
Feasible MMC units are: MA23, MA24, MA6 and U6
Power source
Wire feed unit
MMC &
WDU
Feasible MMC unit is: U8
Summary of Contents for Aristo Mig 3001i
Page 10: ...S0740 800 196 E101019 P76 Mig 3001i 10 ca41_00 ...
Page 11: ...S0740 800 196 E101019 P76 Placement of the circuit boards Mig 3001i 11 ca41_00 ...
Page 12: ...S0740 800 196 E101019 P76 Tig 3001i Placement of the circuit boards Tig 3001i 12 ca41_00 ...
Page 13: ...S0740 800 196 E101019 P76 13 ca41_00 ...
Page 23: ...S0740 800 196 E101019 P76 15AP1 Component positions 23 ca41_15_1 ...
Page 35: ...S0740 800 196 E101019 P76 20AP1 Component positions version 1 35 ca41_20_1 ...
Page 36: ...S0740 800 196 E101019 P76 20AP1 Component positions version 2 36 ca41_20_1 ...
Page 47: ...S0740 800 196 E101019 P76 Power board 15AP1 measuring points 47 ca41f2pwr ...
Page 49: ...S0740 800 196 E101019 P76 49 ca41f2pwr Secondary board 15AP2 measuring points ...