S0740 800 196/E101019/P76
- 52 -
ca41f2soft
12. Secondary side of the main
transformers
S
Measure with the probe
connected to T11 and T22
respectively.
S
The shape of the pulses must
be as in the graph to the right.
13. Measure the output voltage from the
welding current terminals, XS1 and XS2.
It must be about 2.9 to 3.1 V.
Soft starting measuring points
Summary of Contents for Aristo Mig 3001i
Page 10: ...S0740 800 196 E101019 P76 Mig 3001i 10 ca41_00 ...
Page 11: ...S0740 800 196 E101019 P76 Placement of the circuit boards Mig 3001i 11 ca41_00 ...
Page 12: ...S0740 800 196 E101019 P76 Tig 3001i Placement of the circuit boards Tig 3001i 12 ca41_00 ...
Page 13: ...S0740 800 196 E101019 P76 13 ca41_00 ...
Page 23: ...S0740 800 196 E101019 P76 15AP1 Component positions 23 ca41_15_1 ...
Page 35: ...S0740 800 196 E101019 P76 20AP1 Component positions version 1 35 ca41_20_1 ...
Page 36: ...S0740 800 196 E101019 P76 20AP1 Component positions version 2 36 ca41_20_1 ...
Page 47: ...S0740 800 196 E101019 P76 Power board 15AP1 measuring points 47 ca41f2pwr ...
Page 49: ...S0740 800 196 E101019 P76 49 ca41f2pwr Secondary board 15AP2 measuring points ...
Page 53: ...S0740 800 196 E101019 P76 Soft starting measuring points power board 15AP1 53 ca41f2soft ...