S0740 800 196/E101019/P76
- 19 -
ca41_15_1
15AP1 Power board
The power board carries the charging circuit, the gate driver circuit, the switching circuit and
the overvoltage and undervoltage protection circuits.
WARNING!
Dangerous voltage - mains voltage. Never make any measurements on this board
when the machine is connected to the mains supply.
On pages 46 and 50 there are instructions on how to check the power board.
15AP1:1
Internal power supply
The board is supplied with 24 V AC from winding S1 on auxiliary transformer
2TC1. This winding must
never
be mixed-up with the other 24 V winding on
this transformer. 0 VA is galvanic connected to the mains supply.
15AP1:2
Temperature monitoring
NTC IC3 and NTC IC8 are fitted inside the IGBT modules IC3 and IC8.
The temperature monitoring circuit operates when the temperature exceeds
110
_
C and resets at 50
_
C.
Summary of Contents for Aristo Mig 3001i
Page 10: ...S0740 800 196 E101019 P76 Mig 3001i 10 ca41_00 ...
Page 11: ...S0740 800 196 E101019 P76 Placement of the circuit boards Mig 3001i 11 ca41_00 ...
Page 12: ...S0740 800 196 E101019 P76 Tig 3001i Placement of the circuit boards Tig 3001i 12 ca41_00 ...
Page 13: ...S0740 800 196 E101019 P76 13 ca41_00 ...
Page 23: ...S0740 800 196 E101019 P76 15AP1 Component positions 23 ca41_15_1 ...
Page 35: ...S0740 800 196 E101019 P76 20AP1 Component positions version 1 35 ca41_20_1 ...
Page 36: ...S0740 800 196 E101019 P76 20AP1 Component positions version 2 36 ca41_20_1 ...
Page 47: ...S0740 800 196 E101019 P76 Power board 15AP1 measuring points 47 ca41f2pwr ...
Page 49: ...S0740 800 196 E101019 P76 49 ca41f2pwr Secondary board 15AP2 measuring points ...
Page 53: ...S0740 800 196 E101019 P76 Soft starting measuring points power board 15AP1 53 ca41f2soft ...