TIG power sources, calibration of the arc voltage feedback
The arc voltage input can be calibrated using trimming potentiometer R87 on circuit board
20AP1. The board has been calibrated in the factory: further adjustment should not
normally be necessary.
Use an accurately calibrated external voltmeter to measure the voltage at the welding
current terminals.
Disconnect the HF transformer 10TV1 by disconnecting plug 10XS1 from terminal F on
circuit board 10AP1: see the wiring diagram. Set the power source to the MMA welding
mode.
1.
Set a welding current of about 100 A, supplying it to a resistive load so that the voltage
is 25 - 30 V. Using an external voltmeter, measure the voltage across the welding
current terminals.
2.
Using the potentiometer, adjust the value shown on the display so that the voltage
shown is about 0.2 - 1.6 V lower than the voltage at the welding current terminals. This
difference between the measured and the displayed voltages compensates for the
voltage drop in the welding current cables.
Position of potentiometer R87 on circuit board 20AP1
Summary of Contents for Aristo Mig 3001i
Page 10: ...S0740 800 196 E101019 P76 Mig 3001i 10 ca41_00 ...
Page 11: ...S0740 800 196 E101019 P76 Placement of the circuit boards Mig 3001i 11 ca41_00 ...
Page 12: ...S0740 800 196 E101019 P76 Tig 3001i Placement of the circuit boards Tig 3001i 12 ca41_00 ...
Page 13: ...S0740 800 196 E101019 P76 13 ca41_00 ...
Page 23: ...S0740 800 196 E101019 P76 15AP1 Component positions 23 ca41_15_1 ...
Page 35: ...S0740 800 196 E101019 P76 20AP1 Component positions version 1 35 ca41_20_1 ...
Page 36: ...S0740 800 196 E101019 P76 20AP1 Component positions version 2 36 ca41_20_1 ...
Page 47: ...S0740 800 196 E101019 P76 Power board 15AP1 measuring points 47 ca41f2pwr ...
Page 49: ...S0740 800 196 E101019 P76 49 ca41f2pwr Secondary board 15AP2 measuring points ...
Page 53: ...S0740 800 196 E101019 P76 Soft starting measuring points power board 15AP1 53 ca41f2soft ...