ESAB 0401264 User Manual And Spare Parts Download Page 24

Do not dispose of electrical equipment together with normal waste!

According  to  the  European  Directive  2002/96/EC  on  waste  electrical  and 
electronic  equipment  in  accordance  with  the  national  environmental 
standards, electrical equipment that has reached the end of its life must be 
collected  separately  and  delivered  in  environmentally  suitable  recycling 
facility.  In  his  capacity  as  owner  of  the  equipment,  it  is  the  duty  of  this 
information about approved collection systems from your local dealer.

When applying this standard it will be improving the environment and human 
health.

CAUTION!

Class A equipment is not intended for use in residential
locations where the electrical power is provided by the
public low-voltage supply system. There may be potential
difficulties in ensuring electromagnetic compatibility of
class A equipment in those locations, due to conducted
as well as radiated disturbances.

ESAB can provide you with all necessary welding protection and accessories.

2

INTRODUCTION

The LHJ 750 is a direct current rectifier, especially designed for the welding of stick electrode and 
gouging.

Nominal current of 600 A at 60% of the duty cycle.

The welding current is adjusted continuously and precisely through a crank located on the front 
panel.

Has 220 V AC socket for the supply of the auxiliary equipment.

Voltmeter and Ampere meter are optional and can be mounted on to the specific kit.

Forced cooling system, which assures the internal components do not overheat.

The cabinet of LHJ 750 is robust and easily carried through working place. The trolley has break 
device and has lifting holes. 

Duty cicle

Duty cicle is the proportion between the time that a welding machine can provide the maximum 
welding current (load time) and a reference time; according to international standards, reference 
time is 10 minutes.

The 60% Nominal duty cicle means that a machine can repeatedly provide its nominal welding 
current during periods of 6 min. (load) and is followed by a 4-minute rest (the machine does not 
provide  welding  current)  (6  +  4  =  10  min.).  This  process  is  repeatedly  done  so  that  the 
temperature of its internal components do not exceed the project stated limits. The same goes 
for any power factor value. 

In  LHI  Rectifier  the  allowed  duty  cicle  increases  up  to  100%  as  the  used  welding  current 
decreases; conversely, the allowed duty cicle decreases as the welding current increases up to 
its maximum range.

Table 3.1 shows authorised loads for LHJ 750 Rectifier.

3

TECHNICAL DATA

- 24 -

- 25 -

TABLE 3.1

220V - 3Φ / 

+ou-10%

380V - 3Φ / 

+ou-10%

440V - 3Φ / 

+ou-10%

160

93

80

92,5

54

46,7

160

100

80

61

4 x 25mm²

-

750A / 44V

465A / 38,5V

100% of the duty cycle

780 x 950 x 870

225

Current/voltage range GMAW

-10°C á +40°C

Circuit breaker or Fuse Retarded recommended (A)

Dimensions, L x C x A (mm)

Recommended transformer (KW)

Thermal Class

80A/23V- 750A/44V

87

Power factor at maximum current

Open circuit voltage

0,72

Maximum rated current (A)
Maximum effective current (A)

Apparent power (KVA)
Power consumption (KW)

Weight

Protection class

H

Technical Data LHJ 750

Mains voltage

Development technology of equipment

50/60 Hz

Frequency (Hz)

RECTIFIER

LHJ 750

IP22

Operating temperature

61
42

Section of the power supply cable (copper) for up to 3m 
length

Power source

35% of the duty cycle

Allowable loads GMAW

60% of the duty cycle

600A / 44V

Summary of Contents for 0401264

Page 1: ...o revestido e goivagem Manual do usu rio e pe as de reposi o Refer ncia LHJ 750 0401274 LHJ 750 com instrumento digital 0401264 0206767 082015 V lido para n de s rie a partir de FXXXXXX A ESAB se rese...

Page 2: ......

Page 3: ...menta o el trica 9 5 OPERA O 10 5 1 Vis o geral 10 5 2 Controles e conex es 10 5 3 Opera o 11 6 MANUTEN O 11 6 1 Vis o geral 11 6 2 Manuten o preventiva 12 6 3 Manuten o corretiva 12 7 DETEC O DE DEFE...

Page 4: ...cau es de seguran a pertinentes soldagem e corte ou outra opera o aplic vel do equipamento 2 O operador deve garantir que nenhuma pessoa n o autorizada se posicione dentro da rea de trabalho do equipa...

Page 5: ...ificar os olhos e queimar a pele Proteja os olhos e o corpo Use a tela de solda e lente de filtro corretas e vista roupas de prote o Proteja os espectadores com telas ou cortinas adequadas PERIGO DE I...

Page 6: ...ca fornecida pelo sistema p blico de fornecimento de baixa tens o Pode haver dificuldades potenciais em garantir a compatibilidade eletromagn tica de equipamentos classe Anesses locais em fun o de per...

Page 7: ...1 220V 3 10 380V 3 10 440V 3 10 160 93 80 92 5 54 46 7 160 100 80 IP22 Temperatura de opera o 61 42 Se o do cabo de alimenta o cobre para comprimento at 3m Fonte de energia 35 do fator de trabalho Ca...

Page 8: ...a refrigera o 4 1 Geral AVISO PERIGO DE INCLINA O Existe risco de tombamento durante a opera o de transporte caso a m quina esteja com uma inclina o superior a 10 Neste caso providenciar os meios de t...

Page 9: ...s vigentes Afonte de energia LHJ 750 fornecida para liga o a uma rede de alimenta o de 440V Caso a tens o de alimenta o seja diferente as conex es prim rias dever o ser modificadas como indicado no es...

Page 10: ...esligue a alimenta o durante a soldagem com carga 5 2 Controles e conex es Painel frontal 1 Chave Liga Desliga 2 Manivela para regulagem da Corrente de solda 3 L mpada piloto acesa indica que a fonte...

Page 11: ...escala localizada no painel frontal e Iniciar a opera o de soldagem e reajustar a corrente se necess rio 6 MANUTEN O 6 1 Vis o geral Amanuten o peri dica importante para uma opera o segura e confi vel...

Page 12: ...a linha de alimenta o na chave de parede ou disjuntor antes de proceder a qualquer inspe o ou trabalho dentro do equipamento N o permita que pessoas n o treinadas e qualificadas operem ou reparem o eq...

Page 13: ...p gina intencionalmente em branco 13...

Page 14: ...8 ESQUEMAS EL TRICOS 102 100 TOMADA 220V 101 103 L MPADA PILOTO R S T 6 5 CHAVE L D 2 4 1 3 11 7 3 9 4 2 5 12 1 8 10 6 BLOCO DE LIGA O MUDAN A DE TENS O 220 V 380 V 440 V 14...

Page 15: ...K2 6 8 7 5 12 11 10 9 K2 TRANSFORMADOR RECTIFIER BRIDGE M SHUNT K81 83 86 01uFx250V TRANSF AUXILIAR DO VOLT AMP 5 1 2 81 220V K9 83 0 9V 0V K80 81 82 3 4 82 6 85 86 VOLT AMP 85 MOTOR DO VENTILADOR OPC...

Page 16: ...bressalentes e de desgaste originais da ESAB As pe as de reposi o podem ser encomendadas atrav s do seu concession rio mais pr ximo ESAB Consulte a ltima p gina desta publica o Os Equipamentos foram c...

Page 17: ...p gina intencionalmente em branco 17...

Page 18: ...p gina intencionalmente em branco 18...

Page 19: ...tifier User manual and spare parts P N LHJ 750 0401274 LHJ 750 with Volt Amp 0401264 0206767 012013 From serial number FXXXXXX ESAB S A has the right to change technical characteristics of their equip...

Page 20: ......

Page 21: ...pply 26 4 5 Welding circuit 27 5 OPERATION 28 5 1 Overview 28 5 2 Controls and components 28 5 3 Operation 29 6 MAINTENANCE 30 6 1 Overview 30 6 2 Preventive maintenance 30 6 3 Corrective maintenance...

Page 22: ...ety precautions welding and cutting or other applicable operation of the equipment 2 The operator must ensure that no unauthorised person is stationed within the working area of the equipment when it...

Page 23: ...a ARC RAYS Can injure eyes and burn skin Protect your eyes and body Use the correct welding screen and filter lens and wear protective clothing Protect bystanders with suitable screens or curtains FIR...

Page 24: ...e public low voltage supply system There may be potential difficulties in ensuring electromagnetic compatibility of class A equipment in those locations due to conducted as well as radiated disturbanc...

Page 25: ...creases as the welding current increases up to its maximum range Table 3 1 shows authorised loads for LHJ 750 Rectifier 3 TECHNICAL DATA 25 TABLE 3 1 220V 3 ou 10 380V 3 ou 10 440V 3 ou 10 160 93 80 9...

Page 26: ...lation and cleanliness are necessary to cool the equipment and for the operator s safety It is necessary to leave some room around the LHJ 750 with at least 700 mm width for ventilation operation as w...

Page 27: ...cuit voltage drop NOTE DO NOT USE THE NEUTRAL OF THE POWER SUPPLY SYSTEM FOR GROUNDING 4 5 Welding circuit The good functioning of a LHJ 750 also depends on the use of an insulated copper welding cabl...

Page 28: ...NTION Do not turn off the power during welding with charge 5 2 Controls and components Front panel 1 ON OFF switch allows the operator to turn the machine on and off 2 Output NegativeTerminal for weld...

Page 29: ...ngine starts creating an air flow which is needed for the machine refrigeration b Preset the welding current through the crank The crank clockwise rotation increases the current value anti clockwise r...

Page 30: ...tion of electrical wires or cables including work clamp and other insulators Replace them in case they are defective 6 3 Corrective maintenance To assure perfect functioning and performance of the ESA...

Page 31: ...intentionally blank page 31...

Page 32: ...8 ELECTRICAL SCHEMATICS 102 100 101 103 R S T 6 5 2 4 1 3 11 7 3 9 4 2 5 12 1 8 10 6 OUTLET 220V ON OFF SWITCH CONNECTION BOARD PILOT LAMP PRIMARY CONNECTIONS 220 V 380 V 440 V 32...

Page 33: ...1 K2 6 8 7 5 12 11 10 9 K2 RECTIFIER BRIDGE TRANSFORMER M SHUNT K81 83 86 01uFx250V 5 1 2 81 220V K9 83 0 9V 0V K80 81 82 3 4 82 6 85 86 VOLT AMP 85 OPCIONAL AUXILIARY TRANSFORMER DO VOLT AMP FAN ENGI...

Page 34: ...nal spare parts and wear of ESAB Replacement parts can be ordered through your nearest ESAB dealer See the last page of this publication The equipment was constructed and tested according to the stand...

Page 35: ...intentionally blank page 35...

Page 36: ...intentionally blank page 36...

Page 37: ...realizar trabajos con gubia Ref LHJ 750 0401274 LHJ 750 con Voltimetro Amperimetro 0401264 Manual del usuario y repuestos 0206767 012013 V lido para n mero de serie desde FXXXXXX ESAB se reserva el de...

Page 38: ......

Page 39: ...el ctrica 44 5 FUNCIONAMIENTO 45 5 1 Informaci n general 45 5 2 Controles 46 5 3 Operaci n 47 6 MANTENIMIENTO 47 6 1 Informaci n general 47 6 2 Mantenimiento preventivo 47 6 3 Reparaciones 48 7 DETEC...

Page 40: ...espondientes las operaciones de soldadura y corte u otras operaciones aplicabels del equipo 2 El operador debe garantizar que no haya ninguna persona no autorizada en el rea de trabajo cuando se arran...

Page 41: ...l cuerpo Utilice la pantalla para soldar y las lentes filtradoras correctas y use vestimenta protectora Proteja a las personas que se encuentran en el lugar utilizando pantallas o cortinas adecuadas P...

Page 42: ...nte de energ a LHJ 750 es un rectificador de Corriente Constante especialmente proyectado para soldar por proceso de electrodo revestido y realizar trabajos con gubia La corriente se ajusta en forma c...

Page 43: ...0 100 80 61 4 x 25mm 750A 44V 465A 38 5V 100 del ciclo de deber 780 x 950 x 870 225 Rango de corriente voltaje de GMAW 10 C 40 C Interruptor o fusible retardado recomendado A Dimensiones L x C x A mm...

Page 44: ...en la placa nominal La fuente de energ a LHJ 750 est preparada para operar en redes trif sicas de 220 380 440V a 50 60 Hz Debe ser conectada a una l nea el ctrica independiente y de capacidad adecuad...

Page 45: ...nsi n en los circuitos 5 FUNCIONAMIENTO 5 1 Informaci n general ATENCI N Los reglamentos generales de seguridad para el manejo del equipo se encuentran en la secci n 1 L alos con atenci n antes de com...

Page 46: ...gativo para conexi n del cable Masa 5 Terminal de salida positivo para conexi n del cable de corriente 6 Enchufe de 220 VAC para conectar equipos auxiliares 7 Volt metro Amper metro opcional permite o...

Page 47: ...to debe ser realizado por un t cnico entrenado y calificado ATEN O Todas las condiciones de garant a otorgadas por el proveedor caducar n si el cliente intentara realizar por s mismo cualquier tipo de...

Page 48: ...puestos no originales o no aprobados har caducar la garant a otorgada Repuestos ver paginas 53 54 55 56 57 y 58 7 DETECCI N DE DEFECTOS Realice estas verificaciones e inspecciones recomendadas antes d...

Page 49: ...p gina intencionalmente en blanco 49...

Page 50: ...8 ESQUEMAS EL CTRICOS 102 100 101 103 R S T 6 5 2 4 1 3 11 7 3 9 4 2 5 12 1 8 10 6 ENCHUFE 220V L MPARA PILOTO LLAVE E A BLOQUE DE CONEXI N CAMBIO DE TENSI N 220 V 380 V 440 V 50...

Page 51: ...6 8 7 5 12 11 10 9 K2 TRANSFORMADOR PUENTE RECTIFICADOR M SHUNT K81 83 86 01uFx250V TRANSF AUXILIAR DO VOLT AMP 5 1 2 81 220V K9 83 0 9V 0V K80 81 82 3 4 82 6 85 86 VOLT AMP 85 MOTOR DEL VENTILADOR O...

Page 52: ...resa reparadora est obligada a obtener la certeza de que el producto no difiere del modelo referido Los Trabajos de reparaci n y el ctricos deber n ser efectuados por un t cnico autorizado ESAB Utilic...

Page 53: ...rimary connections Tapa de cambio de tensi n A3 1 0904524 Cover Tapa A4 2 0901912 Lifting Hole Cancamo A5 1 0903579 Right Side Tablero Derecho A6 1 0900881 Trolley Carrito A7 1 0900459 Suport Soporte...

Page 54: ...19 Pilot Lamp L mpara Piloto B3 1 0901813 Window Visor B4 1 0904528 Front Panel Tablero Frontal B5 1 0900104 Crank Manivela B6 2 0904244 Output Terminal Conjunto Terminal B7 1 0901887 Outlet Enchufe T...

Page 55: ...e Gu a Izquierda C4 1 0901425 Screw Huso C5 0902712 Core Nut Tuerca del n cleo C6 1 0902006 Shunt Shunt C7 1 0903476 Base Chassis C8 1 0900994 Rectifier Bridges Puentes Rectificadores C9 1 0902339 Pro...

Page 56: ...20 Coil Muele D6 1 0903479 Right Guide Gu a Derecha D7 1 0903223 Fan Suport Soporte del ventilador D8 1 0902849 Fan Engine Motor del ventilador D9 2 0900961 Wheel 12 Rueda 12 D10 1 0903477 Transformer...

Page 57: ...C digo Code Description Descripci n E1 1 0902850 Propeller H lice E2 1 0903481 Rear Panel Tablero Trasero E3 1 0902721 Input Cable Cable TABELA 11 5 TABLE 11 5 TABLA 11 5 Descri o Cabo de alimenta o P...

Page 58: ...ion Descripci n F1 1 0903482 Coil A Bobina A F2 1 0903483 Coil B Bobina B F3 1 0903484 Coil C Bobina C TABELA 11 6 TABLE 11 6 TABLA 11 6 Descri o Bobina C Bobina B Bobina A F1 F2 F3 TRANSFORMADOR VIST...

Page 59: ...ro Amper metro Conjunto de cables porta electrodo y cable masa 800AMP 6M Conjunto de cables porta electrodo y cable masa 600AMP 6M Air gouging torch Volt Amp Kit Electrode holder and work clamp 800A 6...

Page 60: ...p gina intencionalmente em branco intentionally blank page p gina intencionalmente en blanco 60...

Page 61: ...p gina intencionalmente em branco intentionally blank page p gina intencionalmente en blanco 61...

Page 62: ...p gina intencionalmente em branco intentionally blank page p gina intencionalmente en blanco 62...

Page 63: ...63...

Page 64: ...Consum veis e Equipamentos 0800 701 3383 Para localizar o servi o autorizado ESAB mais proximo de sua casa ou empresa acesse www esab com br AM RICA LATINA ESAB Centroamerica S A Ave Ricardo J Alfaro...