![Erreka LINCE LIS424 Installer Manual Download Page 61](http://html1.mh-extra.com/html/erreka/lince-lis424/lince-lis424_installer-manual_2424305061.webp)
Pogramacion_v.01.fm -
24/6/0
9
START UP AND PROGRAMMING
LINCE actuator for sliding gates
57
Advanced Functions Programming (D1= “
A
”)
1
Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2
Press the buttons ^ and
V
until D1 shows the letter
A
flashing. Press ENTER to confirm. D2 flashes.
3
Press the buttons ^ and
V
until the required D2
parameter appears. Press ENTER to confirm. D3 and
D4 flash.
4
Press the buttons ^ and
V
until the required D3 and
D4 value appears (see chart). Press ENTER to
confirm.
5
Press ESC to return to the previous display.
D1
D2
Parameter
D3
D4
P r e -
determined
option
Options or values
A
0
Flashing light
0
1
x
No warning
0
2
With warning
1
Garage light time
0
3
x
3 sec.
0...5. 0...9
59
= 59 sec;
2.5
= 2 min. 50 sec, etc
2
Gate speed
0
1...5
05
01
: minimum speed;
05
: maximum speed
3
Soft stop speed
0
1...5
03
01
: minimum speed;
05
: maximum speed
4
Soft stop function
0
0...5
01
00
: minimum distance;
05
: maximum distance
5
Recede after closing (allows
offsetting of gate expansion)
0
0...9
01
00
: no recede;
09
: maximum recede
6
Maximum force
0
8
x
0...1
0...9
01
: minimum force;
10
: maximum force
7
Closing
photocell
used during
standby (in automatic mode
only)
0
1
Immediate close
0
2
x
Restart standby time
0
3
Has no effect
8
Pushbutton
operation during
standby (in automatic mode
only)
0
1
Immediate close
0
2
x
Restart standby time
0
3
Has no effect
9
Opening mode
0
1
x
Opening in accordance with the mode
selected in the main functions (
F
)
0
2
Community opening
( t h e co n tro l p an e l d o es n o t o b e y t h e
commands during opening)
0
3
Step-by-step opening
(the gate halts if an operation device is
activated during opening. The gate closes
when operated again)
LINCE idiomas.book Page 57 Thursday, June 25, 2009 12:50 PM