54
Installation Manual
START UP AND PROGRAMMING
1
CONNECTION TO THE GRID
1
Plug the actuator into the electricity supply.
2
Press the ENTER button: the display should light up.
Reset (
rS
): after connecting the electricity power
supply and activating any of the operation devices,
the gate closes to the stopper, with the stopper
being assigned the position "gate closed".
During programming, ensure there is no
person or object in the radius of action of the
gate and the operation mechanisms.
2
DISPLAY
Indications during operation:
D1 and D2:
CL
(static)
Gate closed
CL
(flashing)
Gate closed
OP
(static)
Gate open
OP
(flashing)
Gate opening
PC
(flashing)
Pedestrian gate closing
PO
(static)
Pedestrian gate open
PO
(flashing)
Pedestrian gate opening
XX
(countdown)
Gate on standby
STOP
Actuator unlocked
PA
(static)
Pause (operation not complete)
rS
(static)
Gate searching for close position
D3 and D4:
C4
Opening safety device activated
C5
Closing safety device activated
E1
Encoder motor halted
F1
Force limit exceeded
bA
Battery working
Ftço
Photocells defective (testing)
Indications during programming
D1 (Menus):
Shows the selected menu. The following
menus are available:
C
Menu Prior Conditions
P
Menu Recording
F
Menu Main Functions
A
Menu Advanced Functions
ç
Operation Counter
D2 (Parameters):
Shows each parameter of the selected D1 menu.
D3 - D4 (Parameter Values):
Shows the value or option of the selected D2
parameter.
D1
: Display
Menus
D2
: Display
Parameters
D3 - D4
: Display parameter value
The display goes off following a long period
without pressing any key on the control
panel. Press the ENTER key to reactivate.
LINCE idiomas.book Page 54 Thursday, June 25, 2009 12:50 PM