background image

9

Function Settings

Note (Parameter F3)

Please set F3 function after system learning. The LED display 10 to indicate all of the recorded values will increase 1 ampere as 
the over current value. In other words, the LED shows 20 to indicate all the recorded values will increase 2 ampere as the over 
current value. The value can be adjusted by pressing button UP and DOWN. The maximum value is 40(4.0A) and the minimum 
value is 05 (0.5A) 

LED Display               Definition             Parameter 

        Mode 

                                     Description

Photocell1

Photocell2

Buzzer function

Latch release function

Open/Stop/Close/Stop 
function key

Pedestrian Mode function 
key

Auto-Close function key

FC

FD

FE

FF

FG

FH

FI

FC-0
FC-1
FD-0
FD-1
FE-0
FE-1
FF-0
FF-1

FG-1
FG-2
FG-3
FG-4
FH-0
FH-1
FH-2
FH-3
FH-4
FI-0
FI-1
FI-2
FI-3
FI-4

OFF

ON

OFF

ON

OFF

ON

OFF

ON

A key
B key

C key
D key

OFF

A key
B key

C key
D key

OFF

A key
B key

C key
D key

1. The factory setting is "FC-0".

1. The factory setting is "FD-0".

1. The factory setting is "FE-1".

1. if the function is on, the gate will move forward a little  
    before the gate operate for releasing  the Latch 
2. The factory setting is "FF-1".

1. The factory setting is "FG-1".

1. The factory setting is "FH-2".

1. The key is to turn on or off the Auto-Close function.
2. The factory setting is "FI-3".
3. When the  flasher and buzzer is running, the auto 
    closed button has no function till flasher and buzzer 
    finish running.

Summary of Contents for KAIROS MSB-027/01

Page 1: ...puerta insegura o carente de rigidez ni resuelve los defectos debido a una incorrecta insta laci n ni mantenimiento deficiente Compruebe los siguientes puntos antes proceder a la instalaci n 1 Las bis...

Page 2: ...Manual Bloqueo Funcionamiento Motorizado Gire la maneta en sentido horario 1 2 3 Inserte la llave y gire en sentido horario Cierre la tapa 1 2 3 Por favor aseg rese de que B y A tienen valores similar...

Page 3: ...largo de todo el recorrido Fije el soporte delantero Compruebe que el motor queda totalmente nivelado Instale el soporte trasero y f jelo en el pilar Seleccionar la posici n seg n el cuadro del aparta...

Page 4: ...o Fuerza de empuje nominal Longitud de carrera de empuje Extenci n de pistones Tiempo de apertura Ciclo de trabajo Nivel de protecci n IP Temperatura de operaci n Corriente Absorbida A Alimentaci n ab...

Page 5: ...mt3 Lmt2 Lit SKey S1 M2 M1 Lat Ph2 Ph1 PhVcc PhVcc S2 5V ANT GND DKey GND GND GND GND Lmt1 GND J1 Q17 J5 K5 K3 K2 K1 J4 J3 J7 F1 DB1 J8 NC NO CO NC NO CO CO NO NC CO NO NC NC NO CO 1 2 3 4 5 6 7 8 9 1...

Page 6: ...cumplir la configuraci n de F1 0 para seguir ajustando F2 5 pulse SET para regresar a la primera opci n Aparecer en la pantalla F1 y siga los pasos citados 2 y 3 para cumplir la programaci n Despu s d...

Page 7: ...1 Cierra M1 Aviso Cuando cambie el param tro de F2 deber programar el aprendizaje del sistema de nuevo Finalizaci n de aprendizaje del sistema A En la instalaci n de doble hoja Aparecer RUN en el disp...

Page 8: ...dor 2A 3A 4A 5A 100 del total de la velocidad 80 del total de la velocidad Paro suave en apertura y cierre Sin paro suave 70 del total de la velocidad 50 del total de la velocidad 2 seg 3 seg 4 seg 5...

Page 9: ...ra activaci n desactivaci n del cierre autom tico FC FD FE FF FG FH FI FC 0 FC 1 FD 0 FD 1 FE 0 FE 1 FF 0 FF 1 FG 1 FG 2 FG 3 FG 4 FH 0 FH 1 FH 2 FH 3 FH 4 FI 0 FI 1 FI 2 FI 3 FI 4 OFF ON OFF ON OFF O...

Page 10: ...10...

Page 11: ...11...

Page 12: ...34100 078 10 C...

Page 13: ...KAIROS It is not applicable to an insecure or lacking rigidity door nor solves the defects due to incorrect installation or maintenance deficient Check the following points before starting the instal...

Page 14: ...peration Block Motorized Function Then turn clockwise the knob to release the motor 1 2 3 Insert the key and turn clockwise Close the lid of release chamber 1 2 3 Please make sure B and A are similar...

Page 15: ...asily in entire route Fix the front bracket Check the motor is completely leveled Assemble the rear bracket and fix it on the pillar Choose the position Seleccionar la posici n according to the table...

Page 16: ...st Normal Thrust Operation Stroke Piston extention Opening Time Duty Cycle Protection Grade IP Operation temperature Absorbed current A Absorbed Power W Manual Release Enclosure Dimensions 3m 300kg 11...

Page 17: ...4 Lmt3 Lmt2 Lit SKey S1 M2 M1 Lat Ph2 Ph1 PhVcc PhVcc S2 5V ANT GND DKey GND GND GND GND Lmt1 GND J1 Q17 J5 K5 K3 K2 K1 J4 J3 J7 F1 DB1 J8 NC NO CO NC NO CO CO NO NC CO NO NC NC NO CO 1 2 3 4 5 6 7 8...

Page 18: ...F1 0 setting You would contine setting F2 5 please press SET to return the formal option The LED display shows the first two numbers as the first option F1 And then follow the operation and 2 3 until...

Page 19: ...Advise If change the configuration of F2 you should program the system learning again The completion of system learning A For Dual Gate installation Show RUN on LED display B For Single Gate installa...

Page 20: ...0 Full Speed 80 Full Speed Function ON Function OFF 70 Full Speed 50 Full Speed 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec 8 sec 9 sec 10 sec OFF 3 sec 10 sec 20 sec 40 sec 60 sec 120 sec 180 sec 300 sec Mod...

Page 21: ...rian Mode function key Auto Close function key FC FD FE FF FG FH FI FC 0 FC 1 FD 0 FD 1 FE 0 FE 1 FF 0 FF 1 FG 1 FG 2 FG 3 FG 4 FH 0 FH 1 FH 2 FH 3 FH 4 FI 0 FI 1 FI 2 FI 3 FI 4 OFF ON OFF ON OFF ON O...

Page 22: ...10...

Page 23: ...11...

Page 24: ...34100 078 14 B...

Reviews: