17
E
I
!
!
!
!
!
TERMINAL BOARD M3
Terminals 8-11
=
TERMINAL BOARD M4
TERMINAL BOARDS M5-M6 = Dedicated to connection of photocell PRJ38 capsules; see sect. 12 for operation mode.
TERMINAL BOARD M7
TERMINAL BOARD M8
Terminal 20
= Signal output of the OPEN COLLECTOR type, active when door is open or moving; max. load
100mA.
The positive signal is taken from terminal 17.
N.O. EXTERNAL RADAR input. Commands the door opening function.
It is excluded by the digital BATL7 selector in the
or
functions.
It is excluded by the manual BATL9 selector in the
or
functions.
Can also operate as an opening only input (see sect. 7).
Terminals 9-11 = N.O. INTERNAL RADAR input. Commands the door opening function.
It is inhibited by digital selector BATL7 in the
or
functions.
It is inhibited by manual selector BATL9 in the
function.
Can also operate as a closing only input (see sect. 7).
Terminals 10-11 = N.O. START input. Commands the door opening function and starts the initial set-up.
It is inhibited by digital selector BATL7 in the
function.
It is inhibited by manual selector BATL9 in the
function.
Can also operate in the stepping mode (see sect. 7).
Connection to digital selector BATL7. Use a 4-pole flex (0.5 mm in diameter), maintaining the same signal match between
selector and control unit. Maximum cable length 20 meters.
Terminal 12 = 0 (powering negative)
Terminal 13 = DATA ITEM
Terminal 14 = +12 Vdc (powering positive)
Terminal 15 = G (ground)
Terminals 16 (-)-17(+)
= 24 Vdc output, max. 20 W, for powering external accessories.
The line is protected by the 4A fuse F2.
Led L1 indicates that the line is powered.
Terminals 18-19
= N.O. clean contact of relay RL1 that can be used to connect an electro-lock.
Take the power from terminals 16-17 in the case of a 24 V electro-lock.
CONNECTORS J1-J2
= power transformer connection: primary on J1, secondary on J2.
CONNECTORS J4-J10 = wiring of signal conductors between electrical connection part CPB-1 and logic
logic part LGN of the electronic control unit.
CONNECTORS J5-J11 = wiring of powering conductors between parts CPB-1 and LGN of the control unit. The line is
protected by the 8A fuse F3.
CONNECTOR J6
= encoder connection.
CONNECTOR J7
= motor connection.
night lock exit only
night lock
exit only
night lock
entrance only
night lock
night lock
night lock
Route the connection cable well away from sources of electrical interference to prevent false displays on the
selector.
Use the 4-pin terminal board in the
selector kit.
The BATL7 selector kit includes the “LOGIC TAST” interface board, which must be fitted into connector J8 (see
fig. 2) so as to allow the selector to work with the BATL3 control unit.
BATL7
WARNING!