IMPORTANT:
Adjustments that cannot be carried out by the control unit owing to the lack of further potentiometers can only be
made via digital selector BATL7.
Consult sect. 9.2 for instructions about how to regulate the described parameters via selector BATL7.
8) POTENTIOMETER ADJUSTMENTS
TM1
TM2
TM3
TM4
TM5
TM6
TM7
VIA CONTROL
UNIT
FROM
SELECTOR BATL7
Opening speed
Closing speed
Safety sensor inhibiting distance in opening mode
Pushing thrust limitation
Pause time - max 20” - min. 0
Closing upkeep voltage
Wind stop force intensity
Push & Go activating distance
Intensity of final thrust in last closing section to make it easier to fit into electro-
lock
Power of 0.5 sec stroke on closing before opening to release electro-lock. At the
minimum value, the closing stroke is inhibited and the electro-lock is activated at
the same time as the motor starts.
Remote control auto-learning (memorizing)
Push the button on the remote control to save the code.
The top row of input leds will flash simultaneously by way of confirmation.
Note: If the program symbol is
of a light colour, the led is on